Out of stock

PVDF Body Foodcare pH Electrode with BNC Connector for Dairy Products – FC100B

The FC100B is a PVDF body, refillable, double junction pH electrode with a BNC connector. This single ceramic, double junction electrode has a pH indicating probe made of general purpose glass and a food grade plastic body.

This design consideration is ideal for pH measurements in the food industry including sauces, juices, dairy products and other liquid or slurry forms of food. The recommended operating temperature range is from 0 to 80℃.

  • Durable PVDF Body
  • Double Junction Design
  • Refillable Electrode

622.00 AED

Inquire Now
SKU:FC100B

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC100B uses general purpose (GP) glass, spherical bulb, food grade PVDF body, single ceramic frit, double junction and is refillable with 3.5M KCl.

high temperature glass

General Purpose Glass Formulation

General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The FC100B is suitable to use with samples that measure from 0 to 80℃.

high temperature glass

Spherical Bulb

The spherical bulb is for general purpose use within the food industry. Measurements can be made in liquids or slurries that allow easy measurement of solid and semi-solid food products. Other tip shapes include conic for penetration and flat tip for surface measurements.

pvdf body


PVDF Body

Polyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

double junction reference

Single Ceramic Double Junction Reference

The FC100B is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

refillable

Refillable

The FC100B is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.

bnc connector

BNC Connector

The FC100B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Single Junction Versus Double Junction pH Electrodes

junction types

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

Specifications

SKU FC100B
Name PVDF Body Foodcare pH Electrode with BNC Connector for Dairy Products – FC100B
Measurement Range pH: 0 to 13
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl
Body Material PVDF
Tip / Shape spheric (dia: 7.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 80°C (32 to 176°F)
Body Length/Overall Length 120 mm / 160 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use dairy, juice, liquids and slurries measurement in food industry, sauces

Manuals

PVDF Body Foodcare pH Electrode with BNC Connector for Dairy Products – FC100B

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

491.00 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible
Inquire Now

HALO® Bluetooth® Wireless pH Meter for Flat Surfaces - HI14142

989.00 AED
The HI14142 HALO is an innovative pH electrode with Bluetooth® Smart technology designed for flat surfaces Our HALO® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edge®blu. One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology. Status Indicator Visible from a distance, the LED “halo” light flashes to indicate the status of the probe. Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

Foodcare pH Electrode for Semi-Solid with Quick Connect DIN Connector - FC2023

788.00 AED
The FC2023 is an amplified double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The FC2023 electrode features a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration is ideal for pH measurements in dairy products, emulsions, cream, or other semi-solid samples. The recommended operating temperature range is from 0 to 50℃.
  • Low Temperature Glass
  • PVDF Body
  • Open Junction

pH/EC/TDS Multiparameter Probe - HI1285-51

491.00 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor
Back to Top