In stock

Digital Refractometer for Brix Analysis in Foods – HI96801

The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.

  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

869.00 AED

Estimated delivery: 13 - 14 July

SKU:HI96801

The HI96801 portable refractometer converts the refractive index of a food sample to % brix. This conversion is based on the tables found in the ICUMSA Methods Book (International Commission for Uniform Methods of Sugar Analysis) that documents the changes in refractive index with temperature for a percent by weight glucose solution. The HI96801 is ideal for the analysis of fruits, energy drinks, puddings, soy milk, juices, jam, marmalade, honey, soups, jelly, tofu and condiments. The HI96801 is an easy to use tool for measuring sugar in food samples in the field or in the lab.

  • Designed for food sugar analysis
  • Temperature Compensation algorithms based on sucrose solution
  • 0 to 85% brix range with an accuracy of ±0.2%

Making a % Standard Sucrose Solution

To make a Sucrose Solution, follow the procedure below:

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.
  • Tare the balance.
  • Weigh out X grams of high purity sucrose (CAS #: 57-50-1) directly into a beaker.
  • Add distilled or deionized water to the beaker so the total weight of the solution is 100g.
  • Note: Solutions above 60% may need to be vigorously stirred or shaken and heated in a water bath to roughly 40℃ (104℉). Remove solution when sucrose has dissolved and allow to cool before use.

Example to prepare a 25% sucrose solution:

% Brix Sucrose (g) Water (g) Total (g)
25 25.000 75.000 100.000
Diagram showing refractive index behavior in samples

Refractive Index

The HI96801 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96801 uses an LED light, prism and lens to make measurement possible.

Variations in temperature will affect the density of a solution based on the compound that is present. In digital refractometry the use of temperature compensation is necessary for accurate results. The HI96801 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book for a percent by weight sucrose solution.

Features at-a-glance:

  • One-point calibration
      • Calibrate with distilled or deionized water
  • Small sample size
      • Sample size can be as small as 2 metric drops (100 μl)
  • Automatic Temperature Compensation (ATC)
      • Samples automatically compensated for temperature variations
  • Quick, accurate results
      • Readings are displayed in approximately 1.5 seconds
  • Dual-level LCD
      • The dual-level LCD displays measurement and temperature readings simultaneously
  • Stainless steel sample well
      • Easy to clean and corrosion-resistant
  • Battery indicators
      • Battery percent level remaining at startup and low battery indicator
  • Automatic shut-off
      • To conserve battery life the meter shuts off automatically after three minutes of non-use
  • IP65 water resistant protection
      • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.

Specifications

SKU HI96801
Name Digital Refractometer for Brix Analysis in Foods – HI96801
Sugar Content Range 0 to 85% Brix
Sugar Content Resolution 0.1% Brix
Sugar Content Accuracy ±0.2% Brix
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Automatic Shut-Off after three minutes of inactivity
Battery Type/Life 9V / approximately 5000 readings
Dimensions 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight 420 g (14.8 oz.)
Refractometer Light Source yellow LED
Minimum Sample Volume 100 µL (to cover prism totally)
Sample Cell stainless steel ring and flint glass prism
Measurement Time approximately 1.5 seconds

Ordering Info

HI96801 is supplied with battery and instruction manual

Manuals

Digital Refractometer for Brix Analysis in Foods – HI96801

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

GroLine pH 7.01 Calibration Buffer (500mL) - HI7007-050

61.00 AED
HI7007-050 is a high quality pH 7.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

84 µS/cm Conductivity Standard (1 L) – HI7033/1L

77.00 AED
HI7033/1L is a premium quality 84 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

COD Test Tube Heater - HI839800 (230V)

4,600.00 AED
The HI839800 COD Test Tube Heater is an easy to use thermoreactor constructed of durable materials. The aluminum block incorporates a 25 vial capacity and a well for a reference temperature probe. Its well-marked user interface provides intuitive operation, equipped with two arrows to set the built-in timer and a temperature button with two predefined temperature settings: 150℃ and 105℃. Additional features include status indicator lights, a thermal fuse to prevent overheating, and continuous LCD display.
  • Low and high temperature alerts
  • Built-in countdown timer
  • Status indicator lights

Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)

4,584.00 AED
HI83314 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterWastewater Treatment Digestion ParametersMeasures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus
Back to Top
Whatsapp
Product has been added to your cart