HI763100 - Digital EC/Temperature Electrode

1,464 AED
The HI 763100 is a digital conductivity electrode with a built-in temperature sensor. Compared to the amperometric design of other conductivity probes, the HI 763100 is potentiometric probe with platinum sensors which allows for the possibility to measure high or low conductivity ranges using one probe. This electrode features an integrated microchip which stores calibration data, electrode type, and serial number. The HI 763100 is designed for use with Hanna’s edge® pH/EC/DO meter.
  • Digital Probe with Built-in Microchip
  • Internal Temperature Sensor
  • 3.5 mm Connector
1,464 AED

Ammonia Combination Ion-Selective Electrode (ISE) - HI4101

2,566 AED
The HI4101 is a gas sensing, combination ion selective electrode (ISE) for the determination of ammonia (NH3) in solution. Its PTFE membrane allows for ammonia gas diffusion into a thin layer of internal electrolyte. The internal sensing elements are within a durable Delrin® body.The HI4101 is ideal for a variety of applications including water, wastewater, agricultural, and wine applications.
  • Replaceable PTFE membranes
  • Durable Delrin® body
  • Detection from 0.02 to 17, 000 mg/L NH3
2,566 AED

HI76407 Polarographic Dissolved Oxygen Probe with 4 meter cable

801 AED
The HI76407/F is a standard polarographic dissolved oxygen probe for Hanna’s benchtop and portable dissolved oxygen meters. It contains a platinum cathode and silver anode and is for use with HI76407A/P PTFE membrane caps. It’s protective sleeve makes it ideal for use in rugged or demanding environments. Polarographic Sensor Protective Sleeve Integrated Temperature Sensor
801 AED

Flat Tip pH Electrode for Skin and Surfaces with BNC Connector - HI1413B

583 AED
The HI1413B is a glass body, single reference junction pH electrode made with low temperature glass and a BNC connector. This electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe's flat tip makes it ideal for pH measurements on surfaces such as skin, leather, and paper. Open Junction Flat Tip Viscolene Gel Electrolyte
583 AED

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
543 AED

Digital Glass Body pH Electrode with Matching Pin for General Purpose - HI11311

681 AED
The HI11311 is a glass body, refillable, double junction pH electrode with a matching pin and a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI11311 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI11311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector
681 AED

Digital Glass Body pH Electrode for General Purpose - HI11310

601 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector
601 AED

pH Electrode with Conical Tip and BNC Connector - HI1053B

703 AED
The HI1053B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has three ceramic junctions in the outer reference cell for an increased flow rate of reference electrolyte and a conical pH sensing tip that is made with low temperature glass. These design considerations are ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cooler temperatures.
  • Triple Ceramic Junction
  • Double Junction Design
  • Refillable Electrode
703 AED