Electrodes – Hanna Instruments

Showing all 7 results

Sort by

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector
638.00 AED

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

788.00 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
788.00 AED

Digital Glass Body pH Electrode with Matching Pin for General Purpose - HI11311

723.00 AED
The HI11311 is a glass body, refillable, double junction pH electrode with a matching pin and a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI11311 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI11311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector
723.00 AED

Refillable PEI Body pH Electrode with BNC Connector - HI1332B

398.00 AED
The HI1332B is a PEI body, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with general purpose glass, protected by an extension of the durable PEI body. This design consideration is ideal for chemicals, quality control, field applications, and general purpose use.
  • Durable PEI Body
  • Double Junction Design
  • Refillable Electrode
398.00 AED

Gel Filled PEI Body pH Electrode with BNC Connector - HI1230B

422.00 AED
The HI1230B is a PEI body, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass and is protected by an extension of the durable PEI body. This design consideration is ideal for field applications as well as general purpose use.
  • Durable PEI Body
  • Double Junction Reference
  • Low Temperature (LT) Glass
422.00 AED

Digital PVDF Body Foodcare pH Electrode for Dairy Products

788.00 AED
The FC2020 is a digital PVDF body, gel filled pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.The FC2020 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration is ideal for pH measurements in samples such as milk, yogurt, cheese, and other products in the dairy industry. The recommended operating temperature range is from 0 to 60℃.
788.00 AED

pH Electrode for Process Control and Monitoring - HI1001

618.00 AED
The HI1001 is a flow-thru monitoring pH electrode with BNC connection and 3 m cable that has been specifically built for industrial applications. This durable electrode is composed of a PVDF body with a protective PEI sleeve around the glass bulb for resistance against mechanical stress. This sensor provides a rapid response and high accuracy pH measurements for industrial applications.
  • 1/2" NPT threads for in-line mounting
  • PTFE junction
  • BNC universal connector
618.00 AED
Back to Top