Out of stock

HI93703 Portable Turbidity Meter ISO Compliant-kit

The HI93703 is a high accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory. The meter is available as a kit that is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI93703 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements.

Up to three-point calibration

Positive-locking cuvette system

Water-resistant keypad

3,503.00 AED

Inquire Now
SKU:HI93703-11

The HI93703 Portable Turbidity Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the LED light source. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

Features at-a-glance

Single Beam Design – The HI93703 measures turbidity using a light detector at 90° for detection of scattered light. Turbidity measurements can be made in the 0.00 to 1000 FTU range.ISO Compliant – The HI93703 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source. As this meter has been designed to follow this ISO method, the units are displayed in FTU (Formazine Turbidity Unit); FTU is equivalent to the other internationally recognized unit of NTU (Nephelometric Turbidity Unit).Calibration – The HI93703 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two or three-point turbidity calibration can be performed by using the supplied (0, 10, and 500 FTU) standards.AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.Last Calibration Date – The HI93703 allows the user to store the last calibration date. Recall of the last calibration date is simple with a press of the “DATE” button on the face of the meter.Low Battery Indicator – A “LO BAT” indication will appear on the lower right corner of the display when the batteries are low and need to be replaced. At this point, the instrument can still perform approximately 50 measurements. When the battery is too low to perform reliable measurements, a message appears and the meter will automatically switch off.

Significance of Use

Turbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.Turbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity, the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree, as no solution will have zero turbidity.The ISO standard for turbidity measurement uses infrared wavelength of light that is outside the visible spectrum. The primary benefit of the ISO method over the EPA method is the reduction of color interference. The EPA method uses a tungsten lamp that produces light that contains all of the visible wavelengths of light that we see as white. A solution that is colored will be adsorbed by a complementary wavelength of light which will affect the turbidity reading. Since the ISO method is outside the visible wavelength of light the color in the sample does not interfere with the measurement. The USEPA prefers the tungsten lamp since it provides for better accuracy at low ranges and drinking water should not be colored. The requirements of an optical turbidity meter for the measurement of diffuse radiation used in low range measurements (i.e. drinking water) expressed as formazin nephelometric units (FNU) according to ISO 7027:1999 are:Measurement of diffuse radiation for water with low turbidity (0 FNU to 40 FNU)

  • The wavelength of the incident radiation shall be 860 nm.
  • The spectral bandwidth of the incident radiation shall be less than or equal to 60 nm.
  • There shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 1.5o.
  • The measuring angle, theta, between the optical axis of the incident radiation and that of the diffused radiation shall be 90o ±2.5o.
  • The aperture angle should be between 20o and 30o in the water sample.

The HI93703 meets and exceeds the meter criteria specified by ISO 7027.

Principle of Operation

The light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is a‰ffected by many variables, such as wavelength of the incident light, particle size and shape, refractive index, and color. The optical system of the HI93703 includes a LED, and a scattered light detector (90°).The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI93703 is designed to have very low stray light, providing highly accurate results for low turbidity samples.

turbidity measurement
turbidity HI93703 kit
The HI93703C is available as a kit. The kit includes:Portable turbidity meterSample cuvettes (2)Caps (2)Batteries (4 x 1.5V AA) and instructionsHI93703-0 (0 FTU) & HI93703-10 (10 FTU) calibration solutionsHI93703-50 cleaning solutionTissue for wiping cuvettesRugged carrying case
The AMCO AEPA-1 standards for HI93703 ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the turbidity meter.Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 ā„ƒ
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

Specifications

SKU HI93703-11
Name HI93703 Portable Turbidity Meter ISO Compliant-kit
Turbidity Range 0.00 to 50.00 FTU
50 to 1000 FTU
Turbidity Resolution 0.01 (0.00 to 50.00 FTU); 1 (50 to 1000 FTU)
Turbidity Accuracy ±0.5 FTU or ±5% of reading (whichever is greater)
Turbidity Calibration three points (0 FTU, 10 FTU and 500 FTU)
Turbidity Light Source silicon photocell
Turbidity Light Detector infrared LED / life of instrument
Logging Type log on demand
Logging Memory 199 measurements
Connectivity RS232 using HI92000 software
Automatic Shut-Off auto-off after 5 minutes of non-use
Battery Type/Life 1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements
Environment 0 to 50°C (32 to 122°F); RH max 95% (non condensing)
Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6ā€)
Weight 510 g (1.1 lb.)

Ordering Info

HI93703 is supplied complete with glass cuvette, batteries and instructions.

Manuals

HI93703 Portable Turbidity Meter ISO Compliant-kit

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings
Inquire Now

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
Inquire Now

HALOĀ® BluetoothĀ® Wireless pH Meter for Flat Surfaces - HI14142

989.00 AED
The HI14142 HALO is an innovative pH electrode with BluetoothĀ® Smart technology designed for flat surfaces Our HALOĀ® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edgeĀ®blu. One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology. Status Indicator Visible from a distance, the LED ā€œhaloā€ light flashes to indicate the status of the probe. Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.

Titanium Body pH Electrode for Wastewater with Quick Connect DIN Connector - HI12963

807.00 AED
The HI12963 is a titanium body, gel filled, single reference junction pH electrode that has a built-in temperature sensor and a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190 and HI991001. The HI12963 electrode is made with general purpose glass and has an extendable cloth type junction. The design considerations are ideal for measuring the pH in industrial, municipal, and environmental applications.
  • Titanium Body
  • Built-In Temperature Sensor
  • Quick Connect DINĀ 
Inquire Now

Digital Glass Body pH Electrode for Semi-Solids and Emulsions - HI10530

788.00 AED
The HI10530 is a digital glass body, refillable, double junction pH electrode that has a built-in temperature sensor. This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI10530 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass. This design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.
  • Built-In Microchip
  • Built-In Temperature Sensor
  • Triple Ceramic Junction
  • 3.5 mm Connector
Inquire Now

Titanium Body pH/ORP Electrode for Water Treatment Analysis with DIN Connector - HI12973

1,212.00 AED
The HI12973 is a titanium body, gel filled, single reference junction pH electrode with a quick connect DIN connector. This sensing portion of this electrode is made with general purpose glass. The HI12973 also has an extendable cloth type junction along with a built-in temperature sensor and amplifier within a single probe design. This design consideration is ideal for measuring the pH in municipal and industrial wastewater, swimming pools, and various field applications. The HI12973 is designed for use with Hanna’s HI991003 pH meters.
  • Titanium Body
  • Built-In Temperature Sensor
  • Extendable Cloth Junction
Back to Top
Whatsapp
Product has been added to your cart