Out of stock

Titanium Body pH Electrode for Plating Baths with quick connect DIN Connector – HI629113

The HI62911D is a titanium body, polymer filled, double reference junction pH electrode with a DIN connector. The flat tip sensing portion of this electrode is made with general purpose glass.

The HI62911D also has a PTFE type junction along with a built-in temperature sensor and amplifier within a single probe design. This design consideration is ideal for measuring the pH in plating baths. The HI62911D is designed for use with Hanna’s HI99131 pH meter.

  • Titanium Body
  • Built-In Temperature Sensor
  • Recessed, Flat Tip

703.00 AED

Inquire Now
SKU:HI629113

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI629113 uses general purpose (GP) glass, flat tip bulb, titanium body, and PTFE junction with polymer electrolyte.

gp glass

General Purpose Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25℃ while the resistance of LT glass is around 50 megaohms at 25℃. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI629113 is suitable to use with samples that measure from 0 to 80℃.

flat tip bulb

Flat Tip Bulb

The recessed flat tip bulb of the HI629113 is easy to clean and prevents solids in solution from collecting on the sensor. Other tip shapes include conic for penetration and spheric for aqueous measurements.

titanium body

Titanium Body

A titanium body increases immunity to electrostatic and magnetic fields. It also allows for strong corrosion resistance, even in seawater. Out titanium bodied electrodes’ outer casing also serves as a matching pin.

titanium body

Matching Pin

A matching pin is a differential measurement technique used to eliminate ground loops and common mode perturbations for the measurement system. In a system without a matching pin, electrical currents in the sample can affect the reference half-cell voltage that is connected via the liquid junction with the sample. In this case, the reference electrode picks up the electromagnetic fields and the measurement of the pH is altered. The matching pin isolates these current/magnetic fields from the reference electrode. The HI629113 titanium body serves as a matching pin for safe precise pH measurements.

flat tip bulb

PTFE Junction

Porous polytetrafluoroethylene (PTFE) is a hydrophobic material that is available with different porosities. This type of junction is often used on electrodes with polymer electrolytes. Because of its chemical advantages, PTFE is widely used in industrial applications.

DIN connector

DIN Connector

The HI629113 uses a quick connect DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI629113 is designed for use with Hanna’s HI99131 pH meter. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few.

Single Junction Versus Double Junction pH Electrodes

single double junction electrode

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate that can form to clog the junction.

Specifications

SKU HI629113
Name Titanium Body pH Electrode for Plating Baths with quick connect DIN Connector – HI629113
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate PTFE
Type of Electrolyte polymer
Body Material titanium body working as matching pin
Glass Type GP
Tip / Shape flat
Matching Pin yes
Max. Pressure 3.0 bar
Optimum pH Range pH: 0 to 13
Temperature Operating Range 0 to 80°C (32 to 176°F)
Body Length/Overall Length 120 mm / 160 mm
Temperature Sensor yes
Outer Diameter 14 mm
Cable 7-pole; 1 m (3.3 in.)
Connector Type quick connect DIN connector
Amplifier yes
Recommended Use plating

Manuals

Titanium Body pH Electrode for Plating Baths with quick connect DIN Connector – HI629113

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings
Inquire Now

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
Inquire Now

HALO® Bluetooth® Wireless pH Meter for Flat Surfaces - HI14142

989.00 AED
The HI14142 HALO is an innovative pH electrode with Bluetooth® Smart technology designed for flat surfaces Our HALO® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edge®blu. One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology. Status Indicator Visible from a distance, the LED “halo” light flashes to indicate the status of the probe. Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.

Foodcare pH Electrode for Semi-Solid with Quick Connect DIN Connector - FC2023

788.00 AED
The FC2023 is an amplified double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The FC2023 electrode features a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration is ideal for pH measurements in dairy products, emulsions, cream, or other semi-solid samples. The recommended operating temperature range is from 0 to 50℃.
  • Low Temperature Glass
  • PVDF Body
  • Open Junction
Inquire Now

Digital Glass Body pH Electrode for Semi-Solids and Emulsions - HI10530

788.00 AED
The HI10530 is a digital glass body, refillable, double junction pH electrode that has a built-in temperature sensor. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI10530 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass. This design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.
  • Built-In Microchip
  • Built-In Temperature Sensor
  • Triple Ceramic Junction
  • 3.5 mm Connector
Inquire Now

Titanium Body pH/ORP Electrode for Water Treatment Analysis with DIN Connector - HI12973

1,212.00 AED
The HI12973 is a titanium body, gel filled, single reference junction pH electrode with a quick connect DIN connector. This sensing portion of this electrode is made with general purpose glass. The HI12973 also has an extendable cloth type junction along with a built-in temperature sensor and amplifier within a single probe design. This design consideration is ideal for measuring the pH in municipal and industrial wastewater, swimming pools, and various field applications. The HI12973 is designed for use with Hanna’s HI991003 pH meters.
  • Titanium Body
  • Built-In Temperature Sensor
  • Extendable Cloth Junction
Back to Top
Whatsapp
Product has been added to your cart