Out of stock

Photometer for Reducing Sugars in Wine – HI83746

The HI83746 Photometer for Reducing Sugars in Wine combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of reducing sugars in wine within a 0.00 to 50.0 g/L (ppt) range using the HI83746-20 ready made reagents.

  • Built-in Timer
  • Automatic Shut Off
  • Ready-made Reagents

3,278.00 AED

Estimated delivery: 26 - 27 May

Inquire Now
SKU:HI83746-01
The HI83746 photometer is for the determination of reducing sugars in wine. Hanna’s photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length. 

Features at-a-glance

Built-in timer – Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.Zero key – A simple press of the zero key on the face of the meter will account for the color and imperfections in the wine sample before reagent addition.Auto shut-off – Automatic shut-off after 15 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.Battery status indicator – Indicates the amount of battery life left.Error messages – Messages on display alerting to problems including no light, inverted sample, and out of range.Units of measure – Appropriate unit of measure is displayed along with reading.

optical system
Sugar is an essential component in the production of wine. During alcoholic fermentation, yeast consume sugars found in the grape juice, or must, and converts it to ethyl alcohol and carbon dioxide. In the case of certain styles of wine such as semi-sweet or dessert wines, some sugar is allowed to remain post-fermentation. This residual sugar can serve to provide a sweeter character to the final blend or play a role in microbial stability.The primary fermentable sugars found in grapes are glucose and fructose. These two simple sugars are also known as reducing sugars because they contain functional groups capable of being oxidized under certain conditions. After reaction with excess alkaline cupric tartrate (Fehling reagents), the content of reducing sugars can be determined colorimetrically. The Fehling method is not an exact determination but an index of the reducing sugar concentration, because the reaction depends upon the amount and type of reducing sugars present. When the reducing sugar content is known at the beginning of fermentation, the potential alcohol degree can be estimated by multiplying the sugar concentration (in g/L) by 0.06.The HI83746 uses the Fehling method to determine the concentration of reducing sugars less than 50.00 g/L (ppt). When Fehling’s A and Fehling’s B Solutions react with a sample containing reducing sugars, the sample will undergo a color change; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For determination of reducing sugars, a narrow band interference filter at 610 nm (orange) allows only orange light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

Typical content of reducing sugars in must and wine
Mustsweet must20 to 25 %200 to 250 g/L
normal10 to 20 %100 to 200 g/L
in fermentation4 to 12.5 %40 to 125 g/L
Winesweet2.5 to 12.5 %25 to 125 g/L
semi-sweet0.8 to 2.5 %8 to 25 g/L
almost dry0.2 to 0.8 %2 to 8 g/L
dry0 to 0.2 %0 to 2 g/L

Specifications

SKUHI83746-01
NamePhotometer for Reducing Sugars in Wine – HI83746
Reducing Sugars Range0.00 to 50.00 g/L (ppt)
Reducing Sugars Resolution0.25 g/L
Reducing Sugars MethodFehling Method
Precision±0.50 @ 10.00 g/L
Photometer/Colorimeter Light SourceTungsten lamp with narrow band interference filter @ 610 nm
Photometer/Colorimeter Light DetectorSilicon Photocell
DisplayLiquid Crystal Display (LCD)
Power Supply4 (1.5V) AA batteries or 12 VDC adapter
Battery Type/Life1.5V AA batteries
Automatic Shut-Offauto-off after 15 minutes of non-use
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight512 g (18 oz)
Dimensions224 x 87 x 77 mm (8.8 x 3.4 x 3”)

Ordering Info

HI83746 is supplied with glass cuvettes and caps (4), reagents for approximately 20 tests (HI83746-20), HI93703-59 charcoal, 200 µL automatic pipette with two plastic tips, 1000 µL automatic pipette with plastic tips (2), instruction sheet for automatic pipette, spoon, funnel, filter paper (25 pieces), cuvette wiping cloth, 12 VDC adapter, 4 (1.5V) AA batteries, instruction manual, instrument quality certificate, warranty card, and rigid carrying case.

Manuals

Photometer for Reducing Sugars in Wine – HI83746

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Back to Top
    Whatsapp
    Product has been added to your cart