The HI93701-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be display the concentration of chlorine in mg/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg/L free chlorine.
In stock
Free Chlorine Reagents (100 tests) – HI93701-01
The HI93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
- Pre-made reagents for ease of use
- Prepared with high-purity chemicals
- Marked with expiration date and lot number for traceability
101.00 AED
Estimated delivery: 15 - 16 February
SKU:HI93701-01
Specifications
SKU | HI93701-01 |
Name | Free Chlorine Reagents (100 tests) – HI93701-01 |
Package | Packets |
Quantity | 100 tests |
Method | adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample. |
Bestsellers
HI7061L General Purpose Cleaning Solution (500 mL)
61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
- Specially formulated for cleaning electrodes
- Air tight seal to ensure quality
- Expiration date and lot number
Digital Glass Body pH Electrode for General Purpose - HI11310
638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.
The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
- Built-In Microchip
- Spherical Glass Tip
- Double Junction Reference
- 3.5 mm Connector
Inquire Now
COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25
250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
- Pre-dosed reagents for ease of use
- Supplied with certificate of quality
- Marked with expiration date and lot number for traceability
Inquire Now
Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301
510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.
The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.
The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
- Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
- Double Junction Reference
- 3.5 mm Connector
Inquire Now
Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC
734.00 AED
The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.
Multicolor LED Indicator
LED changes color based on status.
Fire Retardant Casing
For additional safety the controllers outer case is made of fire resistant plastic.
Splash Resistant Cover
A clear plastic cover protects the face panel from dirt and liquids.
GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131
703.00 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
- 3 parameters, pH, EC/TDS and temperature, in one meter
- Quick Cal Mode to calibrate pH and EC/TDS with one solution
- TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
HI7004L pH 4.01 Calibration Solution (500 mL)
61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle