Out of stock

COD Low Range Reagent Vials, EPA Method (25 tests) – HI93754A-25

The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground.
    For Professional Use Only.

    250.00 AED

    Estimated delivery: 30 - 31 March

    Inquire Now
    SKU:HI93754A-25

    The HI93754D-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample. During the digestion, hexavalent chromium in the reagent is reduced to trivalent chromium. The amount of reduced chromium is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the COD concentration is displayed in mg/L (ppm) O2. These reagents are designed to be used with samples that have an expected range of 0 to 150 mg/L (ppm) O2.

    Hanna vials contain approximately 3 mL of pre-dosed reagent so the user simply needs to add a small quantity of the sample. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the COD reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized.

    Comparison of Methods

    EPA – The EPA approved method 410.4 for COD determination requires the use of mercuric sulfate (HgSO4). Mercuric sulfate is present in the EPA reagent vials to mitigate the interference of chloride in the measurement sample. This is a common requirement for wastewater treatment plants and food manufacturing facilities which tend to have higher concentrations of chloride present in their effluent. When using reagents that follow the EPA method, it is important to treat used vials as hazardous waste, as mercury waste requires recycling.

    Dichromate – The dichromate method is adapted from the standard EPA and ISO methods for determination of COD, which are approved to measure COD concentrations ranging up to 1500 mg/L O2. For samples with expected concentrations in the high range of 0 to 15000 mg/L O2, the dichromate reagents can be used for accurate COD determination. It is important to treat used vials as hazardous waste, as mercury waste requires recycling.

    Mercury-free – For those who do not wish to handle mercury reagents, our “green, ” mercury-free reagents are available for COD determination. These reagents are more sensitive to chloride interferences, as mercuric sulfate is not present. While the mercury-free reagents are easier to dispose of, they may be unacceptable for reporting purposes.

    ISO – The ISO approved method 15705 for COD determination also requires the use of mercuric sulfate (HgSO4) to reduce the interference of chloride. Containing similar chemical reagents as the EPA method, it is important to treat used ISO vials as hazardous waste, as mercury waste requires recycling.

    Method

    Parameter

    Range (as O2)

    Resolution

    Accuracy

    Reagent Code

    EPA

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI93754A-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI93754B-25

    Dichromate

    COD HR

    0 to 15000 mg/L

    10 mg/L

    ±150 mg/L ±3% of reading

    HI93754C-25

    Mercury-free

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI93754D-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI93754E-25

    ISO

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI93754F-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI93754G-25

    Specifications

    SKU HI93754A-25
    Name COD Low Range Reagent Vials, EPA Method (25 tests) – HI93754A-25
    Package vials
    Quantity 25
    Method dichromate EPA

    Manuals

    COD Low Range Reagent Vials, EPA Method (25 tests) – HI93754A-25

    Bestsellers

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality
    Inquire Now

    COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

    250.00 AED
    The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Inquire Now

    Compact Magnetic Mini-Stirrer (Moss Green) - HI180M-1

    306.00 AED
    HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
    Inquire Now

    HI7022L 470 mV @ 25°C ORP Test Solution (500 mL)

    119.00 AED
    HI7022L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality
    Back to Top
    Whatsapp
    Product has been added to your cart