Out of stock

HI700630P Grease and Fats Acid Cleaning Solution (25 x 20 mL Sachets)

The HI700630P is an effective acidic cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with grease and fats. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.

  • Specially formulated acidic cleaning solution to remove grease and fats from a pH electrode
  • Convenient, one-time use sachets ensure freshness of solution

AED

Estimated delivery: 20 - 21 May

SKU:HI700630P

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

acid cleaning solution

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI700630P is a cleaning solution made specifically for applications that involve the measurement of pH in a meat grease or fats-based solution. 

Light block foil packaging

  • Light-tight packet helps to prevent against degradation by UV light

 

One-time use sachet packets

  • Ensures quality and freshness of solution

 

Each sachet marked with lot number and expiration date

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.

Specifications

SKU HI700630P
Name HI700630P Grease and Fats Acid Cleaning Solution (25 x 20 mL Sachets)
Description acid cleaning solution for meat grease and fats (food industry)
Certificate of Analysis no
Package sachets
Quantity 25
Size 20 mL

Manuals

HI700630P Grease and Fats Acid Cleaning Solution (25 x 20 mL Sachets)

Bestsellers

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

663 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

Ammonia Low Range Reagents (100 tests) - HI93700-01

219 AED
The HI93700-01 are reagents for the colorimetric determination of ammonia in freshwater. There are enough reagents for 100 tests and are for use with Hanna Instruments compatible benchtop and portable meters. These high quality liquid reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date for traceability on each bottle.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

GroLine pH 4.01 Calibration Buffer (500 mL) - HI7004-050

55 AED
HI7004-050 is a high quality pH 4.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Ionic Strength Adjuster (ISA) for Halide ISEs - HI4000-00

303 AED
HI4000-00 is a 500 mL bottle of ionic strength adjuster (ISA) solution for use with bromide, cadmium, chloride, cupric, iodide, and silver/sulfide ion selective electrodes.Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.Required for halide ISE measurementsAir tight bottle with tamper-proof sealClearly marked lot number and expiration date

Portable Yogurt pH Meter - HI99164

1,620 AED
The Hanna Instruments HI99164 is a durable, waterproof, and portable Foodcare pH and temperature meter designed specifically for yogurt analysis. Automatic calibration is performed at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature variations.The HI99164 uses the FC2133 glass body, amplified pH electrode that offers numerous features that improve pH testing for yogurt producers.  The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.
  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof

HI7010/1L pH 10.01 Calibration Solution (1 L)

70 AED
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

4-Ring Conductivity Probe, DIN Connector – HI76302W

812 AED
HI76302W is a four-ring conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3') cable.