Chlorine, Cyanuric Acid, and pH Portable Photometer with CAL Check – HI97725

HI97725 is an advanced portable photometer for the measurement of chlorine, cyanuric acid, and pH in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

Estimated delivery: 6 - 7 December

Inquire Now
SKU:HI97725-

The HI97725 meter measures four important parameters in the treatment and disinfection of swimming pools, spas and cooling towers. HI97725 measures free and total chlorine, pH and cyanuric acid. Each plays a very important role in the treatment of water.

Chlorine is a commonly used for its disinfection properties. The effectiveness of the free chlorine is pH dependent. As pH decreases less than 7.4 the chlorine is found as hypochlorous acid and when pH increases above 7.4, chlorine is predominantly in the hypochlorite ion form. Hypochlorous acid is 100X more effective at killing bacteria than hypochlorite. The chlorine method is an adaptation of the US EPA Method 330.5, DPD Colorimetric Method while the pH is an adaptation of the Phenol Red Method. For chlorine and pH, when the appropriate reagent is added to the sample, is a color change will occur. The greater the concentration, the deeper the color.

Up to 90% of the chlorine can be broken down by sunlight in a matter of hours. Adding cyanuric acid to the water stabilizes the chlorine which will slow down the breakdown process. The cyanuric acid is measured by a turbidimetric method. For cyanuric acid the cloudiness of the sample is dependent on the concentration. The associated color/turbidity change is colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration.

For determination of all four parameters, a narrow band interference filter at 525 nm allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the LED lamp. As the change in color/turbidity of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

photometer optical system
  • LED that generates very little heat.
  • 8 nm narrowband interference filter that is accurate to ±1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output. 
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

On-Screen Features

20mgl Certificate Value Screen

CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.

method option

Setup Options
Backlit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.

Measure Tutorial Screen

Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

1c00min Reaction Time Screen

Reaction Timer
Built-in reaction timer that ensures consistency amongst multiple users.

HI97725 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97725 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. 

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Large Cuvette Size:

  • The sample cell of the HI97725 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97725 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Specifications

SKU HI97725-web
Name Chlorine, Cyanuric Acid, and pH Portable Photometer with CAL Check – HI97725
pH Range 6.5 to 8.5 pH
pH Resolution 0.1 pH
pH Accuracy ±0.1 pH of reading at 25°C
pH Method adaptation of the Phenol Red Method
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading at 25°C
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading at 25°C
Chlorine Method adaptation of US EPA Method 330.5, DPD Colorimetric Method
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading at 25°C
Cyanuric Acid Method adaptation of the Turbidimetric Method
Photometer/Colorimeter Light Source LED with 525 nm bandpass filter
Photometer/Colorimeter Light Detector silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round 24.6 mm diameter (22 mm inside)
GLP yes
Display 128 x 64 pixel B/W LCD with backlight
Logging Memory 50 readings
Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67)
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)

Ordering Info

HI97725C is supplied with CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate, packaged in a rugged, thermoformed carrying case.
HI97725 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.

Manuals

Chlorine, Cyanuric Acid, and pH Portable Photometer with CAL Check – HI97725

Bestsellers

Inquire Now

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

236 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Inquire Now

Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

692 AED
The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

663 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
Inquire Now

edge® Dedicated pH/ORP Meter - HI2002

1,493 AED
Hanna Instruments is proud to introduce the world’s most innovative pH/ORP meter: edge®. edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. edge is a single, easy to use meter that can measure pH and ORP.Advanced pH Electrode Diagnostics edge features advanced pH electrode diagnostics to ensure worry-free measurements. Diagnostics include Hanna’s exclusive CAL Check™ feature that alerts users to potential problems during calibration. The Sensor Check™ feature for glass and junction integrity is enabled when using optional pH electrodes with a matching pin.Capacitive Touch edge features a capacitive touch keypad that gives a distinctive, modern look. The keypad has a fast response and is sensitive enough to be used with laboratory gloves. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue.Large, Easy to Read LCD edge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCDs in the industry.
Inquire Now

Compact Magnetic Mini-Stirrer (Moss Green) - HI180M-1

288 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control

HI7010/1L pH 10.01 Calibration Solution (1 L)

70 AED
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle