In stock

Refillable PEI Body pH Electrode with BNC Connector – HI1332B

The HI1332B is a PEI body, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with general purpose glass, protected by an extension of the durable PEI body.

This design consideration is ideal for chemicals, quality control, field applications, and general purpose use.

  • Durable PEI Body
  • Double Junction Design
  • Refillable Electrode

375 AED

Estimated delivery: 29 - 30 July

SKU:HI1332B

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1332B uses general purpose (GP) glass, spherical bulb, polyetherimide (PEI) body, single ceramic frit, and double junction.

Glass

General Purpose Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25ā„ƒ while the resistance of LT glass is around 50 megaohms at 25ā„ƒ. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI1332B is suitable to use with samples that measure from 0 to 70ā„ƒ.

Spherical Bulb

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

PEI Body

PEI Body

The body of the HI1332B is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.

Double Junction

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

din connector

BNC Connector

The HI1332B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

single vs double junction

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate that can form to clog the junction.

Specifications

SKU HI1332B
Name Refillable PEI Body pH Electrode with BNC Connector – HI1332B
Measurement Range pH: 0 to 13
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl
Body Material PEI
Tip / Shape spheric (dia: 7.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 70Ā°C (32 to 158Ā°F) – GP
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use chemicals, field applications, quality control

Manuals

Refillable PEI Body pH Electrode with BNC Connector – HI1332B

Bestsellers

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

236 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Inquire Now

Conductivity (EC) Controller (0.0 - 199.9 ĀµS/cm) - BL983320-1 | 115/230VAC

692 AED
The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 ĀµS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
Inquire Now

Spare Electrode for PICCOLOĀ® plus pH Tester - HI1295

277 AED
The HI1295 is a spare electrode for the HI98113 PICCOLOĀ® plus pH Tester.

Titanium Body pH Electrode for Wastewater with Quick Connect DIN Connector - HI12963

761 AED
The HI12963 is a titanium body, gel filled, single reference junction pH electrode that has a built-in temperature sensor and a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190 and HI991001. The HI12963 electrode is made with general purpose glass and has an extendable cloth type junction. The design considerations are ideal for measuring the pH in industrial, municipal, and environmental applications.
  • Titanium Body
  • Built-In Temperature Sensor
  • Quick Connect DINĀ 
Inquire Now

Compact Magnetic Mini-Stirrer (Moss Green) - HI180M-1

288 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafeā„¢ mechanism Adjustable speed control
Inquire Now

Titanium Body pH/ORP Electrode for Water Treatment Analysis with DIN Connector - HI12973

1,143 AED
The HI12973 is a titanium body, gel filled, single reference junction pH electrode with a quick connect DIN connector. This sensing portion of this electrode is made with general purpose glass. The HI12973 also has an extendable cloth type junction along with a built-in temperature sensor and amplifier within a single probe design. This design consideration is ideal for measuring the pH in municipal and industrial wastewater, swimming pools, and various field applications. The HI12973 is designed for use with Hannaā€™s HI991003 pH meters.
  • Titanium Body
  • Built-In Temperature Sensor
  • Extendable Cloth Junction
Back to Top
img
Product has been added to your cart