Out of stock

pH Electrode with Clogging Prevention System (CPS™) and quick connect DIN Connector – FC10483

The FC10483 is a glass body, refillable, open junction pH electrode with a quick connect DIN connector that is supplied with the HI99111. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS™) technology and spherical glass sensing bulb made with general purpose glass.

This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode. The FC10483 is a pre-amplified electrode that has a built-in temperature sensor for temperature compensated measurements in a single probe design.

  • Clogging Prevention System (CPS™) Technology
  • Built-In Temperature Sensor
  • Double Junction Design

892.00 AED

Inquire Now
SKU:FC10483

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC10483 uses general purpose (GP) glass, spherical bulb, glass body, sleeve junction with CPS technology, double junction and is refillable with 3.5M KCl making it ideal for wine must, juice, and other samples with a high solids content.

GP Glass Formulation

General Purpose Glass Formulation

General purpose glass as the name implies is a standard glass formulation that is used for general use. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The FC10483 is suitable to use with samples that measure from 0 to 80℃.

Spherical Glass Tip

Spherical Glass Tip

The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.

CPS Sleeve Junction

CPS Sleeve Junction

Clogging Prevention System (CPS™) technology is an innovation for the improvement of pH measurements in samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples that have a high solids content such as wine must or juice. When the junction is clogged, the electrode does not function. The CPS technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes.

Double Junction Reference

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contains sulfides that can cause the silver to precipitate and clog the junction. Clogging of the junction will result in drifty and erratic readings.

Refillable

Refillable

The FC10483 is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode.

Glass Body

Glass Electrode Body

he glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

din connector

DIN Connector

TThe FC1048 has a quick connect DIN connector. This type of connector is proprietary to the meter it is to be used with. The FC10483 is the replacement electrode for the HI99111. Other type of connectors include BNC, screw type, T-type, and 3.5mm.

Single Junction Versus Double Junction pH Electrodes

Single junction vs. double junction electrodes

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihoodof clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

Specifications

SKU FC10483
Name pH Electrode with Clogging Prevention System (CPS™) and quick connect DIN Connector – FC10483
Measurement Range pH: 0 to 12
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate open with ground glass and moveable sleeve, CPS technology
Refill Electrolyte 3.5M KCl
Body Material glass
Tip / Shape dome (dia: 8 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 80°C (32 to 176°F) – GP
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 7-pole; 1 m (3.3 in.)
Connector Type quick connect DIN
Amplifier yes
Recommended Use juice, must, wine

Manuals

pH Electrode with Clogging Prevention System (CPS™) and quick connect DIN Connector – FC10483

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

    491.00 AED
    The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
    • Pre-amplified pH Electrode
    • Amperometric EC/TDS Sensor
    • CAL Check Compatible

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator
    Back to Top
    Whatsapp
    Product has been added to your cart