The FC215D is a glass body, refillable, single junction pH electrode with a DIN connector. This electrode has a triple ceramic junction in the outer reference cell and the pH sensing bulb is made with low temperature glass.

These design considerations are ideal for pH measurements of drinking water and samples with low conductivity. The FC215D is the replacement pH/temperature probe supplied with the HI99192 portable pH meter for drinking water.

  • Triple Ceramic Junction
  • Built-In Temperature Sensor
  • Refillable Electrode

811.00 AED

Inquire Now
SKU:FC215D

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC215D uses low temperature (LT) glass, spherical bulb, glass body, triple ceramic junction and is refillable with 3.5M KCl + AgCl.

low temperature glass

Low Temperature Glass Formulation

The pH measurement of solutions at low temperatures can be difficult due to the effect that temperature has on the resistance of the glass membrane. A standard pH electrode uses general purpose (GP) glass and has a resistance of 100 megaohms at 25ā„ƒ. This resistance will increase as the temperature decreases. If the resistance increase above an optimum range then the measurement will be affected. Some pH electrodes use low temperature (LT) glass for the pH sensitive glass membrane. The resistance of LT glass is around 50 megaohms at 25ā„ƒ. As the temperature of the glass decreases, the resistance of the LT glass approaches the resistance of GP glass. The FC215D is made with LT glass and is suitable to use with samples that measure from 0 to 70ā„ƒ.

spherical bulb

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

glass body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

triple ceramic junction

Triple Ceramic Junction

The triple ceramic junction allows a faster flow rate of electrolyte from the reference cell into the solution. A standard pH electrode will use a single ceramic junction that allows for 15 to 20 µL/hour of electrolyte to flow; the FC215D has three ceramic junctions, providing for 40 to 50 µL/hour of electrolyte to flow. This high flow rate provides faster electrode response and more stable measurement in samples that are low in conductivity, such as drinking water.

triple ceramic junction

Refillable

The FC215D is a refillable probe. It is a single junction pH electrode and uses the HI7071 3.5M KCl + AgCl electrolyte fill solution. If using a refillable pH electrode, the fill cap should be loosened/removed prior to calibration and measurement. Loosening/removing the cap creates positive head pressure in the reference cell increasing the flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

din connector

DIN Connector

The FC215D uses a DIN connector. This type of connector is proprietary to the meter they are to be used with. The FC215D is the replacement electrode for the HI99192. Other type of connectors include BNC, screw type, T-type, and 3.5mm.

Specifications

SKU FC215D
Name pH Electrode for Drinking Water – FC215D
Measurement Range pH: 0 to 12
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate ceramic, triple / 40-50 µL/h
Refill Electrolyte 3.5M KCl + AgCl
Body Material glass
Tip / Shape spheric (dia: 9.5 mm)
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 70°C (32 to 158°F)
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type DIN
Amplifier yes
Recommended Use low conductivity solutions, potable water

Manuals

pH Electrode for Drinking Water – FC215D

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

edgeĀ® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5ā€ thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Back to Top
Whatsapp
Product has been added to your cart