Out of stock

pH and EC Transmitter with Isolated Output

The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna’s EC probes that incorporate an NTC sensor for temperature compensation.

The HI98143 is available in four models based on the analog output signal required.

  • Blind transmitter for pH and EC (up to 10 mS/cm)
  • Choice of analog output in voltage or current
  • Powered or loop powered analog outputs

Inquire Now
SKU:HI98143

Direct Connection

Direct connection of the probes to the transmitter assures a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.

Output Signals

Four models are available, transmitting a 0-1 V, 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance.

Automatic Temperature Compensation

Compensation for the effects of temperature for EC measurements is performed by the transmitters’ Automatic Temperature Compensation circuitry.

Connectivity

The transmitter can be connected to any pH or conductivity controller, recorder, PC or any data monitoring device that accepts 0 to 1 V, 0 to 4 V or 4 to 20 mA input.

Simple Design

Probes connectors, power supply, contacts, and calibration trimmers are easy to reach directly on the front panel

Versatile Use

For in-line applications, the recommended pH electrode is the HI1001 while the conductivity probe is the HI3001. HI1001 is a combined double junction pH electrode with BNC and 3m cable; HI3001 is a 4-ring conductivity probe with platinum sensors and an int

Specifications

SKU HI98143-web
Name pH and EC Transmitter with Isolated Output
pH Range 0 to 14
pH Accuracy ±0.5% f.s.
pH Calibration Manual, 2 point, through trimmers
EC Range 0 to 10 mS/cm
EC Accuracy ±2% f.s.
EC Calibration 0 (offset) and 5 mS/cm (slope) trimmers
EC/TDS Temperature Compensation Automatic from 0 to 60 ĀŗC
Temperature Correction Coefficient ß=2%/ ºC
Cell Type 4-ring EC probes
EC/TDS Probe Four (ring) pole probe with built in NTC sensor
Analog Output HI98143-01 0-1 V
HI98143-04 0-4 V
HI98143-20 4-20 mA (passive)
HI98143-22 4-20 mA (active)
Power Supply 12-24 Vdc
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
IP Rating IP54
Dimensions 160 x 105 x 31mm (6.3 x 4.1 x 1.2”)
Weight 280 g (9.9 oz.)

Manuals

pH and EC Transmitter with Isolated Output

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

Original price was: 110.00 AED.Current price is: 90.00 AED.
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

Original price was: 80.00 AED.Current price is: 64.00 AED.
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7010/1L pH 10.01 Calibration Solution (1 L)

Original price was: 95.00 AED.Current price is: 78.00 AED.
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

1413 µS/cm Conductivity Standard (1 L) – HI7031/1L

Original price was: 90.00 AED.Current price is: 78.00 AED.
HI7031/1L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

Original price was: 250.00 AED.Current price is: 247.00 AED.
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Free Chlorine Reagents (100 tests) - HI93701-01

    Original price was: 101.00 AED.Current price is: 100.00 AED.
    The HI93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high-purity chemicals
    • Marked with expiration date and lot number for traceability
    Back to Top