Out of stock

Panel-mounted Conductivity & TDS Controller – HI710-with RS485 digital output

The HI710 series of controllers offer state of the art specifications for your process control. They can be configured for ON/ OFF, proportional, PI or PID control. Thanks to our exclusive technology, they can be customized to best fit your application.

  • CAL Check™ alerts users of calibration status.
  • Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily.
  • With self-diagnostic features and extractable terminals, installation and maintenance are fast and simple.

2,250 AED

Estimated delivery: 10 - 11 September

Inquire Now
SKU:HI710222-2

HI 710 series controllers are real time microprocessor-based EC controllers. They provide accurate measurements, flexible ON/OFF or proportional control capabilities, analog input and output, RS485 port, dual setpointand alarm signal.The system is composed of a case inside which the signal conversion circuitry, the microprocessor circuitry and the outputpower drivers are contained.

With self-diagnostic features and extractable terminals, installation and maintenance are fast and simple. Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily. The controllers can operate with four-ring probe or 4-20 mA signal. They accept probes with or without a built-in Pt100 temperature sensor.

HI710 Series Conductivity and TDS Controller’s FEATURES/BENEFITS:

Display

  • Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.

Indicator LEDs

  • Four LEDs are provided for signaling the energizing of relay 1 and 2 (yellow LEDs) and alarm relays (a greenand a red LED).

PC Connectivity (HI710222 only)

  • RS485 standard is a digital transmission method that allows long lines connections. Its current-loop system makes this standard suitable for data transmission in noisy environments. Data transmission from the instrument to the PC is possible with the HI 92500 Windows® compatible application software offered by Hanna Instruments.

Friendly Interface

  • A menu-driven display aids the user throughout the operations with running messages and clear prompts. All relevant parameters can be simply adjusted and will remain memorized until overwritten.

Programmable Hold System

  • The hold function allows the user to stop the regulating action of the controller for programmable time periods. It is possible to activate the hold periods in correspondence to programmed operations, such as plant maintenance and cleaning procedures.

Programmable Cleaning Cycles

  • Heavy-duty applications often require almost continuous probe maintenance. Elements such as suspended solids, fat, oils, pigments and microorganisms can quickly deposit and soil the electrode. Programmable cleaning cycles allow for scheduled maintenance to keep the probe functioning optimally.

Automatic Temperature Compensation

  • A 2-wire Pt100 can be connected to ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Good Laboratory Practice (GLP)

  • Last calibration data internally recorded for traceability including calibration date and time, cell constant, calibration solution values.

Relays

  • 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)

Calibration

  • Automatic 1 point calibration. alibration and Setup procedures allowed only through an unlock password.

Mult Range Conductivity / TDS Measurment

  • Four different EC working ranges (0 to 199.9μS; 0 to1999μS; 0 to 19.99mS; 0 to 199.9mS)
  • Four different TDS working ranges (0 to 100.0ppm; 0 to1000ppm; 0 to 10.00ppm; 0 to 100.0ppm) for HI 710models.

Specifications

SKU HI710222-2
Name Panel-mounted Conductivity & TDS Controller – HI710-with RS485 digital output
EC Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
EC Resolution 0.1 µS; 1 µS; 0.01 mS; 0.1 mS
EC Accuracy ±0.5% f.s. (EC)
EC Calibration automatic or manual at 1 point
TDS Range 0.0 to 100.0 mg/L (ppm); 0 to 1000 mg/L (ppm); 0.00 to 10.00 g/L (ppt); 0.0 to 100.0 g/L (ppt)
TDS Resolution 0.1 ppm; 1 ppm; 0.01 g/L (ppt); 0.1 g/L (ppt)
TDS Accuracy ±0.5% f.s.
EC/TDS Temperature Compensation automatic or manual, -10 to 100°C with adjustable temperature coefficient from 0.00 to 10.00%/°C
EC to TDS Conversion Factor adjustable from 0.00 to 1.00
Temperature Range -10.0 to 100.0°C
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5°C (0 to 70°C); ±1°C (outside)
Analog Input Signal 4-20 mA
Analog Ouput Signal analog: isolated 0-1 mA, 0-20 mA and 4-20 mA; 0-5 VDC, 1-5 VDC and 0-10 VDC or digital: RS485 bi-directional opto-isolated
Power Consumption 15 VA
Over Current Protection 5A, 250V fast fuse
Enclosure Single case ½ DIN
Installation Category II
Panel Cutout Panel cutout: 140 x 140 mm / Instrument: 144 x 144 x 170 mm
Power Supply 230 ±10% Vac , 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 144 x 144 x 170 mm
Weight 1.6 kg (3.5 lb.)

Ordering Info

Each HI710 model is supplied with mounting brackets and instructions.

Manuals

Panel-mounted Conductivity & TDS Controller – HI710-with RS485 digital output

Bestsellers

Inquire Now

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

236 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Inquire Now

Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

692 AED
The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
Inquire Now

® Dedicated pH/ORP Meter - HI2002

1,493 AED
Hanna Instruments is proud to introduce the world’s most innovative pH/ORP meter: edge®. edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. edge is a single, easy to use meter that can measure pH and ORP. Advanced pH Electrode Diagnostics edge features advanced pH electrode diagnostics to ensure worry-free measurements. Diagnostics include Hanna’s exclusive CAL Check™ feature that alerts users to potential problems during calibration. The Sensor Check™ feature for glass and junction integrity is enabled when using optional pH electrodes with a matching pin. Capacitive Touch edge features a capacitive touch keypad that gives a distinctive, modern look. The keypad has a fast response and is sensitive enough to be used with laboratory gloves. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue. Large, Easy to Read LCD edge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCDs in the industry.
Inquire Now

Compact Magnetic Mini-Stirrer (Moss Green) - HI180M-1

288 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

663 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
Inquire Now

Nitrate-Nitrogen Portable Photometer - HI96728

801 AED
The HI96728 is no longer available.Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.Both meters use the same reagents.
Back to Top
img
Product has been added to your cart