Out of stock

Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-GP – General Purpose-Pt1000

Hanna presents a series of combination pH and ORP electrodes, including more than 300 models, incorporating over 20 years of electrode manufacturing experience.
The most advanced feature of this series is the electrode shape with a flat tip, virtually eliminating deposits that can foul the electrode, significantly reducing necessary maintenance. This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.

  • PVDF body
  • Self-cleaning flat tip sensor for significantly reduced maintenance.
  • Provided with an internal matching pin that can avoid typical problems caused by grounding loop current.
  • 3/4″ NPT external thread on both ends for easy installation

1,456.00 AED

Estimated delivery: 26 - 27 May

Inquire Now
SKU:HI1006-2405

A Worldwide Leader in Electrode Manufacturing

Since the beginning of the 1990’s Hanna has been a leader in the research & development of pH and ORP electrodes. Today, Hanna is proud to
present the latest family of industrial electrodes, the Flat Tip Series, which completes the wide range of Hanna probes for any process application.
All Hanna industrial pH and ORP electrodes are combination type, i.e. the reference half cell and the measurement half cell are assembled in the
same body.

Flat tip pH Electrode

Advantage of flat tip electrodes

  • In a continuous in-line installation, the glass sensor of the pH electrode can be physically damaged by solution streams containing suspended solids.
  • Our Flat Tip electrodes are the best answer to this problem. The flat tip virtually eliminates deposits that can foul the electrode, significantly reducing necessary maintenance.
  • This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.
matching pin

Each pH electrode is provided with an internal matching pin that can avoid typical problems caused by grounding loop current, such as:

  • progressive damage of the electrode
  • fluctuating measurements
  • poor process regulation

In many industrial applications, especially in plating baths, grounding loop current is a very common problem.
When a traditional electrode/controller system is used with the electrode reference connected both to the electrode and to the instrument, a current flow occurs through the reference half cell, causing fluctuations in reading and serious damage to the Ag/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above, the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly, the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.

Flat tip pH dimensions

Installation

These electrodes have been designed with ¾” external thread on both ends for easy installation. HANNA instruments® also provides a series of probe holders for in-line, tank or by-pass installations for these electrodes, as shown below.

Front thread ¾” NPT

  • Direct in-line installation ¾” standard tee 
  • Immersion installation in vessel, tank, plating bath with HI 60501 (PVC) or HI 60503 (PVDF) electrode holders with adjustable immersion level: min 10 cm, max 70 cm 
  • Direct pipe installation with HI 60542 PVC electrode holder, 2″ thread

Back thread ¾” NPT

  • Immersion installation with ¾” threaded pipe 
  • By-pass installation with HI 60545 By-pass electrode holder “Loop” configuration Liquid inlet: ¾” Liquid outlet: ¾

HI1006 Series Flat Tip pH Electrode FEATURES/BENEFITS:

Junction

Three junction types are available:

  •  Annular non-clogging PTFE junction, for testing solutions with high content of suspended solids or for high pressure installation
  • Open junction, ideal for wastewater analysis
  • Ceramic junction

Glass Sensor

  • Hanna has developed four types of specialized glass. First is a durable sensor glass for general purpose, industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process and streams significantly increase the electrode life

Temperature Sensor

  • The pH electrodes with built-in 3-wire Pt100 or Pt1000 temperature sensor allow for the temperature compensation of pH readings as well as temperature measurements.

Connection Type

  • Electrodes are wired for direct connection to a transmitter or process controller, or with the standard BNC connector.

Built-in Amplifier

  • Models with a built-in amplifier are necessary for long distance measurements, where it is not possible to install a transmitter. The internal amplifier can be powered directly from select Hanna process controllers or a power source that supplies the appropriate voltage.

Cable Length

  • Non-amplified electrodes are provided with a 5, 10 or 15 m cable (16’, 33’ or 49’)

PVDF Body

  • The PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications, and guarantees a high chemical and mechanical resistance. These characteristics makes the PVDF material the most recommended for many industrial applications. PVDF is also non-toxic and compatible with food applications.

Specifications

SKU HI1006-2405
Name Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-GP – General Purpose-Pt1000

Manuals

Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-GP – General Purpose-Pt1000

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass

    ORP Electrode for Process Control and Monitoring - HI2001

    680.00 AED
    HI2001 is an economical process ORP probe with a BNC connector. The BNC connector is universal and works with any ORP (mV) meter that has a BNC probe input. The HI2001 is a double junction design with a polymer reference for long life in many common industrial applications. 1/2" and 3/4" NPT threads for in-line and submersion mounting Chemically resistant PTFE junction Universal BNC connector
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
    Back to Top
    Whatsapp
    Product has been added to your cart