The HI3618D is a glass body, refillable, single junction ORP electrode with a DIN connector. This electrode has a single ceramic junction in the outer reference cell and the ORP sensing pin is made with platinum.

This design consideration is ideal for laboratories and general purpose ORP measurements.

  • Built-In Temperature Sensor
  • Refillable Electrode
  • Platinum Sensing Pin

723.00 AED

Inquire Now
SKU:HI3618D

Hanna Instruments offers a wide variety of ORP electrodes that are designed for many different applications. The type of material used for the sensing pin, type of glass used for body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

=The HI3618D uses a platinum pin, glass body, single ceramic junction and is refillable with 3.5M KCl + AgCl.

Platinum Pin

Platinum Sensing Pin

The HI3618D ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

Glass Body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Ceramic Junction

Single Ceramic Junction

The outer junction of an electrode, also known as a salt bridge, is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

Refillable

Refillable

The HI3618B is a refillable probe. Since it is a single junction ORP electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable ORP electrode, the fill cap should be removed prior to measurement. Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

DIN connector

DIN Connector

The HI3618D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few. The HI3618D ORP probe is used witht eh HI8314 portable meter.

Specifications

SKU HI3618D
Name Glass Body ORP Electrode with DIN Connector – HI3618D
Measurement Range ORP: ±2000 mV
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl + AgCl
Body Material glass
Tip / Shape platinum pin
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range -5 to 70°C (23 to 158°F)
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 5-pole; 1 m (3.3 in.)
Connector Type DIN
Amplifier yes
Recommended Use laboratory general purpose

Manuals

Glass Body ORP Electrode with DIN Connector – HI3618D

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

HI7010/1L pH 10.01 Calibration Solution (1 L)

77.00 AED
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator