Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)
14,584.00 AED4,125.60 AED -
COD Test Tube Heater - HI839800 (230V)
14,600.00 AED4,140.00 AED -
-
HI7082L Electrolyte Solution 3.5M KCl (500 mL)
1302.00 AED271.80 AED -
HI7061L General Purpose Cleaning Solution (500 mL)
161.00 AED54.90 AED
- You cannot add that amount to the cart — we have 1 in stock and you already have 1 in your cart. View cart
Out of stock
Ammonia Medium Range Portable Photometer – HI96715
The HI96715 is no longer available.
Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.
Both meters use the same reagents.

850.00 AED
Inquire NowThe HI96715 portable photometer is for the measurement of ammonia (as NH3-N) in freshwater samples. Hanna’s portable photometers feature an advanced optical system; the combination of a light emitting diode (LED), a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check⢠feature utilizes ready-made standards traceable to a NIST Standard for performance verification and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
*Reagents ordered separately

CAL Check⢠standards with certificate
The HI96715-11 CAL Checkā¢standards are used for calibration and performance verification of photometers with the CAL Check⢠function.
Supplied with Certificate of Analysis
- Lot number
- Expiration date
- Standard value @ 25 ā
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage

Specifications
| SKU | HI96715-web |
| Name | Ammonia Medium Range Portable Photometer – HI96715 |
| Ammonia Range | 0.00 to 9.99 mg/L (ppm) (as NHā-N) |
| Ammonia Resolution | 0.01 mg/L |
| Ammonia Accuracy | ±0.05 mg/L ±5% of reading |
| Ammonia Method | adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method |
| Photometer/Colorimeter Light Source | light emitting diode |
| Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 466 nm |
| Battery Type/Life | 9V battery |
| Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Weight | 360g (12.7oz.) |
| Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Info
HI96715 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.