Out of stock

Additional Reagent for Titratable Acidity in Water Titrator – HI84430-58

The HI84430 titrator is designed to determine both low and high range values of acidity in water.  Water samples containing polyvalent cations (such as iron, aluminium, chromium, manganese, etc) may react slowly with the titrant, causing a drifting endpoint. It is necessary to add several drops of the HI84430-58 additional reagent solution (hydrogen peroxide) to such samples in order to increase the rate of hydrolysis of the metal ions present.

  • Pre-Measured Solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal to ensure quality

Inquire Now
SKU:HI84430-58

The HI84430-58 is a 30 mL bottle of hydrogen peroxide solution that is used to treat water samples containing hydrolyzable salts or polyvalent cations (such as iron, aluminum, manganese, and chromium) to accurately determine acidity values.

The determination of water acidity is based on the neutralization of all acidic species contained in water samples by titration with a basic titrant solution:

H+ + OH → H2O

The endpoint of an acid base titration corresponds stoichiometrically to the complete neutralization of the acids present. Water acidity results from strong and weak acids as well as from the hydrolysis of salts. Due to these more complex mixtures, endpoints for water acidity are arbitrarily fixed on practical considerations. Unpolluted surface waters contain carbon dioxide as the main acidic component, and titration of these samples corresponds to the stoichiometric neutralization of carbonic acid with sodium hydroxide. The titration to pH 8.3 represents total acidity. The titration to pH 3.7 represents strong acidity from polluted water. If the samples are suspected to contain hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese), it is necessary to pretreat the samples with HI84430-58 reagent.

The HI84430 titrator is designed to determine the acidity of waters by potentiometric titration in both a low range (15 to 500 mg/L as CaCO3) and high range (400 to 4000 mg/L as CaCO3). Both total and strong acidity can be determined by the HI84430. If the measured pH is lower than 3.7 both total and strong acidity can be determined. If the sample is greater than pH 3.7 then only total acidity can be determined.

Replacement reagents required to operate the HI84430:

Low Range – 15 to 500 mg/L as CaCO3

High Range – 400 to 4000 mg/L as CaCO3

Pump calibration standard

HI84430-55M

HI84430-55M

Titrant solution

HI84430-50

HI84430-51

Additional reagent*

HI84430-58

HI84430-58

* Used with samples containing hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese)

Specifications

SKU HI84430-58
Name Additional Reagent for Titratable Acidity in Water Titrator – HI84430-58
Description Additional Reagent for Titratable Acidity in Water Titrator
Package bottle
Quantity 1
Size 30 mL

Manuals

Additional Reagent for Titratable Acidity in Water Titrator – HI84430-58

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.