Out of stock

4-Ring Conductivity Probe, DIN Connector – HI76302W-4m (13′)

HI76302W is a four-ring conductivity probe with internal temperature sensor, DIN connector.

Inquire Now
SKU:HI76302W-00/4

Specifications

SKU HI76302W-00/4
Name 4-Ring Conductivity Probe, DIN Connector – HI76302W-4m (13′)
Tip / Shape 4-ring probe
Conductivity Measuring Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm
Conductivity Measuring Accuracy ±1% F.S. (excluding probe error)
EC/TDS Temperature Compensation Range 10 to 50˚C (50 to 122˚F) with β = 2%/˚C
Cable 1 m (3.3 in.)
Connector Type DIN

Manuals

4-Ring Conductivity Probe, DIN Connector – HI76302W-4m (13′)

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

pH/EC/TDS Multiparameter Probe - HI1285-51

491.00 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

GroLine pH 7.01 Calibration Buffer (500mL) - HI7007-050

61.00 AED
HI7007-050 is a high quality pH 7.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

491.00 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible

pHep+ Waterproof Pocket pH Tester with 0.01 pH Resolution - HI98108

221.00 AED
HI98108 pHep+ is a compact, waterproof pH tester with a range from 0.00 to 14.00 pH, resolution of 0.01 pH, and ±0.10 pH accuracy.  
  • Compact, waterproof design
  • Calibration up to 3 points
  • For environmental, field, and laboratory testing
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.
Back to Top
Whatsapp
Product has been added to your cart