Waterproof portable thermistor thermometer for brewing – HI935012

HI935012 is a waterproof portable thermistor thermometer designed for brewing industry. The HI935012 is supplied with the FC762N2 stainless steel probe that is 1 meter in length and is used to measure the temperature of mash in the center of a tank. This meter can be used at other critical points of the brewing process including the wort boil and fermentation.

  • CAL Check to ensure internal electronics are within acceptable tolerances
  • Probe Error Messages
  • High accuracy ±0.1℃/±0.2℉

634.00 AED

Inquire Now
SKU:HI935012

The HI935012 is a waterproof portable thermistor thermometer made for the brewing professional that needs to measure the temperature in the center of a tank or vessel. The HI935012 is supplied with the FC762N2 thermistor probe that is made of stainless steel and is 1-meter long. For a fast and accurate measurement, the pre-calibrated semi-conductor sensor is located in the tip of the probe.

The HI935012, as a meter, can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 150 ℃ (302 ℉) and offers a very high accuracy of ±0.1 ℃ (±0.2 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for an abnormal drift of the internal electronics. Using a properly prepared ice bath, the meter and probe can be calibrated by the user. Additional features to have confidence in the measurements include a battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected

There are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.

 HI935012 brewing thermometer

CAL Check

The calibration check (CAL Check) feature of the HI935012 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly

Long Battery Life

The thermometer has an exceptional battery life of approximately 4500 hours using three common AAA batteries. The battery percent level is displayed when powered on alerting the user to the remaining battery life

Probe Error Messages

The “NO PROBE” message is displayed on the meter when a probe is not attached or there is a break in the cable

hi935012 with carrying case

1M Stainless Steel Probe

The supplied FC762N2 thermistor probe that is 1 M (39″) long and 10 mm (0.39″) in diameter. This extra-long probe allows for the measurement of temperature in the middle of tank to make sure it is consistent throughout.

Supplied with Carrying Case

The HI935102 is supplied with a soft carrying case that holds both the probe and the meter. There is a pouch inside for easy access to the meter.

Supplied with Instrument Quality Certificate

HI935012 with the FC762N2 are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA, or to internationally acceptable physical standards

Additional Features/Benefits:

Large LCD

  • An enhanced LCD displays the measurement reading in ℃ or ℉, stability indicator, error messages, and low battery indicator.

Stability Indicator

  • An hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes, the indicator disappears and a reading can be taken.

Automatic Shut-off

  • The meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.

Ergonomic, rugged, waterproof (IP65) design

  • For additional protection the HI710027 shockproof rubber boot is available as an accessory.

Specifications

SKU HI935012
Name Waterproof portable thermistor thermometer for brewing – HI935012
Thermistor Temperature Range -20.0 to 120.0 ℃ ; -4.0 to 248.0 °F
Thermistor Temperature Resolution 0.1 ℃; 0.1 °F
Thermistor Temperature Accuracy ± 0.1 ℃; ± 0.2 °F
Temperature Probe Thermistor probe
Automatic Shut-Off user selectable: off, 8 or 60 m in.
Battery Type/Life 1.5V AAA battery (3 pcs.) / approximately 4500 hours of continuous use
Environment rated operating conditions: -20 to 50°C (-4 to 122°F); limiting conditions: -30 to 50°C (-22 to 122°F); storage and transportation conditions: -40 to 70°C (-40 to 158°F); relative humidity: 100%
Dimensions 140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)
Weight 175 g (6.27 oz.)

Ordering Info

HI935012 is supplied with FC762N2 1M thermistor stainless steel probe, batteries, instruction manual, instrument quality certificate, and protective carrying case.

Manuals

Waterproof portable thermistor thermometer for brewing – HI935012

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Back to Top
    Whatsapp
    Product has been added to your cart