In stock

Ultra Pure Water EC/Resistivity Waterproof Portable Meter – HI98197

The HI98197 is a rugged portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. The HI98197 is supplied complete with all accessories necessary to perform high purity water measurements packaged into a durable carrying case. The accessories include a stainless steel flow cell and a threaded four ring conductivity probe that allows for high resolution 0.001 µS/cm for conductivity and 0.1 Mω * cm for resistivity readings.

  • Stainless steel flow cell
  • Four ring conductivity/resistivity probe
  • 0.001 µS/cm resolution

5,459.00 AED

Estimated delivery: 26 - 27 May

SKU:HI98197

The HI98197 is supplied with a specialized HI763123 four-ring conductivity probe that not only allows for a 0.001 μS/cm resolution measurement but also has screw type threads for insertion into the HI605453 AISI 316 stainless steel flow cell. The HI763123 has a built-in temperature sensor and a adjustable temperature coefficient for accurate readings that cover a complete range with a single sensor. The four-ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763123 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.

High purity water used in power generation, semiconductor manufacturing and other industries can be difficult to measure can be difficult to measure due the ability of carbon dioxide (CO2) to diffuse into water and forming carbonic acid (H2CO3). The carbonic acid will dissociate into hydrogen ions (H+) and bicarbonate ions (HCO3). These ions will increase the conductivity and decrease the resistivity of the water. In order to measure high purity water accurately it is necessary to perform a continuous flow measurement. The HI98197 uses the HI763123 four ring probe with a threaded connection that is screwed into a stainless steel body flow cell. The flow cell is connected to a water source to determine the conductivity or resistivity whichever is preferred. The HI98197 is an ideal meter for monitoring the mixed bed resin or equivalent system that produces high purity water of 18.2 MΩ * cm at 25 ℃.

Expanded Ranges – HI98197 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98197 also has ranges for TDS, resistivity and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.

USP – HI98197 can be used to perform all three stages of USP <645> method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.

5-Point Calibration – Calibration can be performed up to five points with seven preprogrammed conductivity standards. For salinity (% NaCl range), HI7037 standard allows users to perform a one-point calibration.

Temperature Compensation – EC and TDS measurements are fully customizable and include: cell constant selection between 0.0 and 10.000 and a selection of linear, non-linear (natural water) or no temperature compensation. The temperature compensation coefficient range is configurable from 0.00 to 10.00%/℃ with a choice of reference temperatures of 15℃, 20℃ and 25℃.

TDS Conversion Factor – The conductivity to TDS factor is adjustable from 0.40 and 1.00.

User Profiles – The HI98197 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.

Logging – The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

Good Laboratory Practice (GLP) – GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.

Contextual Help – Access Help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

Graphic LCD – The high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

Thermoformed Carrying Case – The compact, durable HI720197 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter and probe, beakers and conductivity standards.

Specifications

SKU HI98197
Name Ultra Pure Water EC/Resistivity Waterproof Portable Meter – HI98197
EC Range 0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater)
EC Calibration automatic up to five points with seven memorized standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
TDS Calibration based on conductivity calibration
EC/TDS Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Temperature Correction Coefficient 0.00 to 10.00 %/°C
EC to TDS Conversion Factor 0.40 to 1.00
Reference Temperature 15°C, 20°C and 25°C
EC/TDS Multi-range Measurement Modes autorange, autoend, lock and fixed range
Salinity (% NaCl) Range 0.0 to 400.0 %
Salinity (% NaCl) Resolution 0.1 %
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Max. one point only in % range (with HI7037 standard)
Salinity (PSU) Range 0.00 to 42.00 (PSU)
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% of reading
Salinity (PSU) Calibration based on conductivity calibration
Salinity Range 0.00 to 80.00 (ppt)
Salinity Resolution (ppt) 0.01 ppt
Salinity Accuracy (ppt) ±1% of reading
Salinity Calibration (ppt) based on conductivity calibration
Resistivity Range 1.0 to 99.9 Ω cm; 100 to 999 Ω cm; 1.00 to 9.99 KΩ cm; 10.0 to 99.9 KΩ cm; 100 to 999 KΩ cm; 1.00 to 9.99 MΩ cm; 10.0 to 100.0 MΩ c
Resistivity Resolution 0.1 Ω cm; 1 Ω cm; 0.01 KΩ cm; 0.1 KΩ cm; 1 KΩ cm; 0.01 MΩ cm; 0.1 MΩ cm
Resistivity Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater)
EC/TDS Probe HI763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included)
Logging Type Log-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Logging Memory up to 10
Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Automatic Shut-Off user selectable: 5, 10, 30, 60 min or can be disabled
Battery Type/Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)

Ordering Info

HI98197 is supplied with HI763123 conductivity probe, HI605453 stainless steel flow cell, HI7033M 84 µS/cm calibration solution (230 mL), HI7031M 1413 µS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case.

Manuals

Ultra Pure Water EC/Resistivity Waterproof Portable Meter – HI98197

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart