Out of stock

Total Phosphorus Low Range Reagents – HI93758C-50

The HI93758C-50 are reagents that follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method for the determination of low range total phosphorus using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-made reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

240 AED

Estimated delivery: 10 - 11 September

Inquire Now
SKU:HI93758C-50

The HI93758C-50 reagent kit contains 50 ready-to-use vials of HI93758V-0AH, 1 bottle of HI93758C-0 solution, 50 packets of potassium persulfate reagent, and 50 packets of HI93758-0 phosphorus reagent. These high quality reagents follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. In this method, the reaction between orthophosphate and the reagent causes a blue tint in the sample. The amount of phosphorus is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the concentration is displayed in mg/L (ppm) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.15 mg/L (ppm) phosphorus.

Hanna vials contain pre-dosed reagent so the user simply needs to add a small quantity of the sample to the vial followed by heating 30 minutes at 150℃ and cooling, then the addition of the NaOH solution to use as the blank, followed by the addition of the phosphorus powder reagent to measure the concentration. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized.

Specifications

SKU HI93758C-50
Name Total Phosphorus Low Range Reagents – HI93758C-50
Package Vials, bottle, and packets
Quantity 50 tests
Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method

Manuals

Total Phosphorus Low Range Reagents – HI93758C-50

Bestsellers

Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

481 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector
Inquire Now

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

236 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
Inquire Now

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Inquire Now

Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

692 AED
The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
Inquire Now

® Multiparameter EC/TDS/Salinity Meter - HI2030

2,530 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

Digital Glass Body pH Electrode for Semi-Solids and Emulsions - HI10530

743 AED
The HI10530 is a digital glass body, refillable, double junction pH electrode that has a built-in temperature sensor. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI10530 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass. This design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.
  • Built-In Microchip
  • Built-In Temperature Sensor
  • Triple Ceramic Junction
  • 3.5 mm Connector