Out of stock

Reference Electrode for ISE Half-Cells – HI5315

The HI5315 reference electrode is a silver/silver chloride double junction half-cell designed for use with ion selective electrode (ISE) and pH half-cells.The reference electrode provides a stable reference voltage when paired with a sensing half-cell. The external reference electrolyte chamber is refillable and easy to drain with the quick flush sleeve design. The internal reference elements are housed within a durable polyetherimide (PEI) body. A fast responding liquid junction, excellent reproducibility, and ease of use will mark this reference as the “best” in your lab.

  • Skirted cone geometry
  • Quick flush sleeve
  • For use with ISE and pH half-cells

1,159.00 AED

Inquire Now
SKU:HI5315

The HI5315 reference electrode is a potentiometric half-cell that contains a silver/silver chloride (Ag/AgCl) reference housed within a PEI plastic body. HI5315 provides the electrolytic contact necessary to permit a voltage gradient to be measured across a sensing membrane, such as an ISE or pH half-cell.Hanna’s HI5315 reference electrode is designed with a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the assembled electrode makes it easy to empty the electrolyte fill solution and replace when necessary.For the HI5315 to measure specific ions accurately, the appropriate fill solution must be used in the external electrolyte chamber.Recommended ISE Fill Solutions

CodeDescriptionFill Solution
HI4002Bromide half-cellHI7072
HI4003Cadmium half-cellHI7072
HI4004Calcium half-cellHI7082
HI4007Chloride half-cellHI7072
HI4008Cupric half-cellHI7072
HI4009Cyanide half-cellHI7072
HI4010Fluoride half-cellHI7075
HI4011Iodide half-cellHI7072
HI4012Lead/Sulfate half-cellHI7072
HI4013Nitrate half-cellHI7078
HI4014Potassium half-cellHI7076
HI4015Silver/Sulfide half-cellHI7072

When taking measurements of specific ions, it is also important that the ionic strength of the standards and sample be adjusted to a high and constant value with ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free silver ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements.

Features at-a-glance

Skirted Cone Geometry – The highly stable and reproducible voltage of the HI5315 reference electrode is due to its specially designed skirted cone geometry. A narrow ring shaped opening between the outer sleeve of the electrode and the lower edge of the skirt shaped inner body forms a stable and highly accurate liquid junction.Quick Flush Sleeve – With a simple press of the upper cap of the assembled reference electrode, the fill solution quickly drains out of the body. Such a design allows for easy cleaning of the electrode or replacement of fill solution if using with more than one sensing half-cell.Durable PEI Body – The probe body of the reference electrode is composed of durable, chemically inert polyetherimide (PEI) plastic.Banana Plug Connection – The HI5315 has a banana plug connector for easy connection to any meter with a reference probe input.

Specifications

SKUHI5315
NameReference Electrode for ISE Half-Cells – HI5315
Descriptionhalf-cell
Temperature Range0 to 80 °C
Body MaterialPEI
Body Length/Overall Length120 mm
Outer Diameter12 mm
Cablecoaxial; 1 m (3.3’)
Connector Typebanana

Manuals

Reference Electrode for ISE Half-Cells – HI5315

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal
Back to Top
Whatsapp
Product has been added to your cart