In Stock

Pump Calibration Standard for Titratable Acidity in Dairy Mini Titrator – HI84529-55

The HI84529-55 is a 230 mL bottle of pump calibration standard that is used to calibrate the dosing system of the HI84529 Titratable Acidity Mini Titrator for Dairy Analysis.A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84529 in determining the exact titratable acidity. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.

  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

113.00 AED

Estimated delivery: 31 July - 1 August

SKU:HI84529-55

The HI84529-55 is a 230 mL bottle of pump calibration standard solution that is used for both low and high range determination of acidity in dairy products.The amount of pump calibrations performed will vary on the range selected.The determination of acidity is made according to a neutralization reaction in which the acids found in dairy products are neutralized by a base. In the United States the acidity of dairy products is usually expressed in terms of lactic acid (% l.a.). Other units of measure include degree Soxhlet Henkel (°SH), degree Dornic (°D) and degree Thorner (°Th).Analysis of titratable acidity in dairy, as performed on the HI84529 mini titrator, utilizes a simple sample preparation, a high quality titrant dosing pump, potentiometric endpoint detector, and automatic computations. As the titrant comes pre-standardized, it is important to determine the amount of titrant delivered by the dosing pump by performing a pump calibration procedure. In this procedure, the analysis of a known volume of a known solution is titrated with to a fixed pH endpoint determined by the FC260B pH electrode and HI5315 reference electrode.The HI84529-55 pump calibration solution is used for both the low and high ranges, but the volume used will based on the selected range. The Low Range 20 range uses 1 mL while the Low Range 50 uses 2 mL; the High Range 20 range uses 10 mL of the pump calibration solution. The pump calibration procedure should be performed anytime the titrant, syringe, tubing or pH electrode is replaced. It is recommended to do a pump calibration every time a new set of titrations are to be performed.Replacement reagents required to operate the HI84529 include:

Low Range 20 (LR 20) – %l.a.: 0.01 to 0.20 Low Range 50 (LR 50) – %l.a.: 0.01 to 0.20 High Range 20 (HR 20) – %l.a.: 0.1 to 2.0
Pump calibration standard HI84529-55 HI84529-55 HI84529-55
Titrant solution HI84529-50 HI84529-52 HI84529-51

Specifications

SKU HI84529-55
Name Pump Calibration Standard for Titratable Acidity in Dairy Mini Titrator – HI84529-55
Description Pump Calibration Standard for Titratable Acidity in Dairy Mini Titrator
Package bottle
Quantity 1
Size 230 mL

Manuals

Pump Calibration Standard for Titratable Acidity in Dairy Mini Titrator – HI84529-55U

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

GroLine pH 7.01 Calibration Buffer (500mL) - HI7007-050

61.00 AED
HI7007-050 is a high quality pH 7.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

84 µS/cm Conductivity Standard (1 L) – HI7033/1L

77.00 AED
HI7033/1L is a premium quality 84 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

COD Test Tube Heater - HI839800 (230V)

4,600.00 AED
The HI839800 COD Test Tube Heater is an easy to use thermoreactor constructed of durable materials. The aluminum block incorporates a 25 vial capacity and a well for a reference temperature probe. Its well-marked user interface provides intuitive operation, equipped with two arrows to set the built-in timer and a temperature button with two predefined temperature settings: 150℃ and 105℃. Additional features include status indicator lights, a thermal fuse to prevent overheating, and continuous LCD display.
  • Low and high temperature alerts
  • Built-in countdown timer
  • Status indicator lights

Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)

4,584.00 AED
HI83314 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterWastewater Treatment Digestion ParametersMeasures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus