Out of stock

Portable pH/mV/°C Meter with Recorder Output – HI8915

HI8915 is a portable pH/mV/℃ meter that combines accurate pH measurements with a recorder output capability and automatic temperature compensation.

  • Two recorder output terminals make it possible to attach a plotter or recorder directly to the meter for a hard copy of the measurements.
  • Pressing the HOLD key will freeze the reading on the display.
  • Calibration is performed using the two trimmers on the front panel.

1,196.00 AED

Inquire Now
SKU:HI8915

Two recorder output terminals on the front panel make it possible to attach a plotter or recorder directly to the meter for a hard copy of the measured values.

The large LCD displays a different indicator for each operational mode to identify the current measurements.

Pressing the ‘HOLD’ key will freeze the reading on the display. Calibration is performed using two trimmers on the front panel.

Specifications

SKU HI8915
Name Portable pH/mV/°C Meter with Recorder Output – HI8915
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.01 pH
pH Calibration manual, 2 point, through offset and slope trimmers
mV Range -1999 to +1999 mV
mV Resolution 1 mV
mV Accuracy ±1 mV
Temperature Range 0.0 to 100.0°C
Temperature Resolution 0.1°C
Temperature Accuracy ±0.5°C
Temperature Compensation automatic, 0 to 70°C (32 to 158°F) or fix at 25°C (77°F) without temperature probe
Battery Type/Life 1 x 9V alkaline batteries
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 185 x 82 x 53 mm (7.3 x 3.2 x 2.1”)
Weight 265 g (9.3 oz.)

Ordering Info

supplied complete with HI1230B pH electrode, HI7669AW temperature probe, calibration screwdriver, battery and instructions

Manuals

Portable pH/mV/°C Meter with Recorder Output – HI8915

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality

    Free Chlorine Reagents (100 tests) - HI93701-01

    101.00 AED
    The HI93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high-purity chemicals
    • Marked with expiration date and lot number for traceability

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator
    Back to Top
    Whatsapp
    Product has been added to your cart