Out of stock

Pool Line pH Controller and Dosing Pump – BL100

Engineered to be an inexpensive solution for homeowner and maintenance companies to maintain the ideal pH at all times of a swimming pool or hot tub. The BL100 Pool Line pH Controller and Dosing Pump is a complete solution with both a process controller and a chemical dosing pump. Simply insert the probe and injection valve in-line with the re-circulation pump and supply the acid to be dosed.

  • All in one solution for maintaining the proper pH
  • Industrial process probe with 1/2″ NPT threads for insertion into re-circulation line
  • Input for level controller or flow switch

Estimated delivery: 8 - 9 September

Inquire Now
SKU:BL100

BL100 pH Controller and Dosing Pump is a system engineered for maintaining the pH of swimming pools, hot tubs, and spas. Typically chlorine, whether liquid or solid, is alkaline and will raise the pH of the water that it is added to. As the pH increases above pH 7.4, a form of chlorine known as hypochlorite ion (OCl) increases. This form of chlorine is 100 time less effective at killing bacteria as compared to the other form of chlorine known as hypochlorous acid (HOCl). For this reason it is important to maintain the correct pH level in order to ensure that the more powerful hypochlorous acid form is available for disinfection. The BL100 was developed to be an inexpensive solution for the consumer to maintain the ideal pH at all times. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.

bl100

Multi-color LCD

The BL100 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.

Intuitive LCD

Both pH and temperature are displayed with status icons that show when the pump is dosing and the control mode status.

Programmable Alarm System

Hanna controllers allow users to enable or disable the low and high level alarms for pH. When an alarm is activated, all dosing will stop. For added safety, the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.

On-Screen Features

flow rate

Adjustable Flow Rate
The flow rate from the dosing pumps is adjustable from 0.5 to 3.5L/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point .

Automatic Proportional Pump Control

Automatic Proportional Pump Control
The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed, will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.

 Acid Tank Level/Flow Switch Input

Acid Tank Level/Flow Switch Input
The BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

Built-in Dosing Pump

Pooline Peristaltic Pump

Peristaltic Dosing Pump

The BL100 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.

Brushless Motor

The brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.

Long-life Peristaltic Tubing

The industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.

pH electrode with flow cell

pH probe mounted in flow thorugh cell

Three Configuration Options

The BL100 is available in multiple configurations including a meter only, meter and probe, and
a complete package that includes bypass loop
and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.

HI10053 Amplified pH/Temperature Probe

The BL100 uses the HI10053 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector. The built in amplifier helps to reduce electrical noise from recirculation pumps to provide for a stable, reliable measurement. The pH glass used is ideal for low conductivity water and provides for fast response..

NPT Threads for In-line and Tank Mounting

The ABS body of the probe has a 1/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3/4” NPT threads for submersion/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .

Specifications

SKU BL100-web
Name Pool Line pH Controller and Dosing Pump – BL100
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.10 pH
pH Calibration User calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH)
Process calibration: single point, adjustable (±0.50 pH around measured pH)
pH Temperature Compensation Automatic
pH Dosing Set Point adjustable from 6.00 to 8.00 pH
pH Proportional Band adjustable from 0.10 to 2.00 pH
pH Hysteresis Band adjustable 0.10 to 1.00 pH
Temperature Range -5.0 to 105.0 °C (23.0 to 221.0 °F)
Temperature Resolution 0.1 °C (0.1 °F)
Temperature Accuracy ±0.5 °C (±0.9 °F)
Dosing Control proportional and on/off control
Alarm Relay Set Point triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values
Over Dosing Control overtime protection (1 to 180 m in. or Off)
Digital Input Signal external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn’t work)
Power Consumption 15 VA
Enclosure wall mounted with built-in pump
pH Electrode HI10053 pH/temperature probe with quick connect DIN connector (supplied)
Power Supply 100 – 240 Vac, 50/60 Hz
Environment 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing
IP Rating IP65
Dimensions 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)
Weight 910 g (32 oz)

Ordering Info

BL100-00 is supplied with BL100 controller, HI10053 pH/temperature probe, 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.

BL100-10 is supplied with BL100 controller, HI10053 pH/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.

BL100-20 is supplied with BL100 controller, HI10053 pH/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.

Manuals

Pool Line pH Controller and Dosing Pump – BL100

Bestsellers

Inquire Now

Universal Process Controller - HI510-0320 - controller with 3 relays and 2 analog outputs

2,912 AED
HI510 is designed to adapt to a user’s unique process control requirements. The controller has a large backlit dot matrix display for easy viewing and provides for an intuitive interface for setup options. The controller utilizes multi-color LEDs for easy viewing of the instruments’ status including relay activation, in alarm mode, or in hold status. All programming operations are done through the low profile vulcanized rubber keypad or using the RS485 connection to a PC operating the HI92500 Windows® compatible software.
  • Digital input for pH and ORP probes
  • Up to 5 relays for control and cleaning sequence
  • Up to 4 analog output for control and monitoring
Inquire Now

Universal Process Controller - HI510-controller with 5 relays and 4 analog outputs

3,640 AED
HI510 is designed to adapt to a user’s unique process control requirements. The controller has a large backlit dot matrix display for easy viewing and provides for an intuitive interface for setup options. The controller utilizes multi-color LEDs for easy viewing of the instruments’ status including relay activation, in alarm mode, or in hold status. All programming operations are done through the low profile vulcanized rubber keypad or using the RS485 connection to a PC operating the HI92500 Windows® compatible software.
  • Digital input for pH and ORP probes
  • Up to 5 relays for control and cleaning sequence
  • Up to 4 analog output for control and monitoring
Inquire Now

Pool Line pH Controller and Dosing Pump - BL100

Engineered to be an inexpensive solution for homeowner and maintenance companies to maintain the ideal pH at all times of a swimming pool or hot tub. The BL100 Pool Line pH Controller and Dosing Pump is a complete solution with both a process controller and a chemical dosing pump. Simply insert the probe and injection valve in-line with the re-circulation pump and supply the acid to be dosed.
  • All in one solution for maintaining the proper pH
  • Industrial process probe with 1/2" NPT threads for insertion into re-circulation line
  • Input for level controller or flow switch
Inquire Now

Pool Line ORP Controller and Dosing Pump - BL101

Engineered to be an inexpensive solution for homeowner and maintenance companies to maintain the ideal ORP at all times of a swimming pool or hot tub. The BL101 Pool Line ORP Controller and Dosing Pump is a complete solution with both a process controller and a chemical dosing pump. Simply insert the probe and injection valve in-line with the re-circulation pump and supply the oxidizer (i.e. chlorine) to be dosed.
  • All in one solution for maintaining the proper ORP value
  • Industrial process probe with 1/2" NPT threads for insertion into re-circulation line
  • Input for level controller or flow switch
Inquire Now

Swimming Pool Controller with Built-in Dosing Pumps - BL120

Control with ConfidenceThe BL120 Swimming Pool Controller is a complete system designed for maintaining swimming pool, hot tub, and spa disinfection water quality. The BL120 is available in two configurations. The basic version is the in-line model which allows for direct installation of probe and chemical injection fittings into existing piping. The other version is a panel mounted version with a bypass flow cell. The bypass flow cell allows for calibration and maintenance of the probe without having to shut down the recirculation pump. Additional features of the BL120 include LED indicators for dosing, meter status and service, real-time graph display, programmable alarms, and password protection.
Inquire Now

Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps - BL122

Pool Line pH and ORP Controllers with Hanna Cloud Connectivity BL122 and BL123 are designed to maintain constant pH and ORP (disinfectant) levels in swimming pools, hot tubs, and spas and offer the added benefit of allowing remote connection and access to devices via the Hanna Cloud web app. Available in two configurations, the basic version allows for direct installation of probe and chemical injection fittings into existing piping. Also available is a panel mounted version with a bypass flow cell that allows for calibration and maintenance of the probe without having to shut down the re-circulation pump.
Inquire Now

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series

The Hanna Instruments PCA310, PCA320, PCA330 and PCA340 series of chlorine, pH, ORP and temperature analyzers are microprocessor controlled, process analyzers which continuously monitor a sample stream for chlorine content, pH, ORP and temperature values.
  • 4 models available for monitoring chlorine, pH, and ORP levels
  • Two separate selectable 0-20 or 4-20 mA signal output (PCA340 only)
  • User-friendly interface simplifies setup and maintenance
Back to Top
img
Product has been added to your cart