Out of stock

Chlorine, pH, ORP, and Temperature Analyzers – PCA300 Series

The Hanna Instruments PCA310, PCA320, PCA330 and PCA340 series of chlorine, pH, ORP and temperature analyzers are microprocessor controlled, process analyzers which continuously monitor a sample stream for chlorine content, pH, ORP and temperature values.

  • 4 models available for monitoring chlorine, pH, and ORP levels
  • Two separate selectable 0-20 or 4-20 mA signal output (PCA340 only)
  • User-friendly interface simplifies setup and maintenance

Estimated delivery: 16 - 17 February

Inquire Now
SKU:PCA310
PCA chlorine analyzer
Chlorine

From drinking and wastewater treatment to pool and spa sanitation, monitoring chlorine levels has an important bearing on public health as well as ROI and efficiency for heating system and industrial applications.

As one of the oldest and most common forms of disinfection, chlorine improves water quality by destroying disease-producing microorganisms, and by reacting with other organic and inorganic substances. Chlorine levels must be actively monitored to ensure sufficient chlorine is present for disinfection, as well as to control adverse effects such as taste, odor, and potential reactions with organic matter to form harmful disinfection byproducts.

Chlorine is a strong oxidising agent that destroys mostly organic pollutants and bacteria and can combine with nitrogen containing compounds, forming chloramines. When dosing chlorine for disinfection, only a portion of the dosed chlorine remains active to actually continue the disinfection process.

PCA chlorine Analyzer
DPD Colorimetric method

The PCA Analysers uses DPD Colorimetric method in which N, N-Diethyl-p-phenylenediamine indicator and a buffer are mixed together with the sample. The resulting chemical reaction causes a magenta color to form in the presence of chlorine. The color intensity is proportional to the concentration. The color intensity is measured photometrically (light source at a specific wavelength and a photodetector) and converted to chlorine concentration, in mg/L, which is displayed on the front panel. The sampling interval for chlorine measurement is adjustable from 3 to 90 minutes. The PCA has a dosing relay for the addition of chlorine by a dosing pump or chlorine generator when a reading is below the programmable set point. The technology used by the PCA for chlorine measurement is the same as that found in portable and benchtop colorimeters providing for consistent results when performing process verification with one of those types of meters.

Amplified pH electrode

The PCA Family also uses the HI1005 amplified pH electrode with a built in pt100 temperature sensor and matching pin to measure both pH and temperature. The built in amplifier and matching pin provide for exceptional performance against any electrical noise generated by pumps and motors.

Analog output

The PCA340 features two selectable 0-20 or 4-20 mA signal output that are scalable for the transmission of readings to external recording devices. The analog outputs can also be set for dosing and used with dosing pumps that accept a 4-20 mA analog input. The analog outputs can be used for any of the three measured parameters.

PCA Series Controller FEATURES/BENEFITS:
Backlit LCD Display
  • The PCA Family has a backlit display that is easy to read from a distance and allows for up to three parameters to be displayed at a time.
Nema 4X Protection
  • The PCA Analysers are enclosed in waterproof casing for superior protection against the elements. The front door of the case has a window for the measurement display while also shielding the DPD reagents from UV light to prevent premature degradation.
DPD Chlorine Measurement Method
  • The DPD colorimetric method is one of the most common and reliable methods to measure chlorine. The PCA Family can use either free or total chlorine reagents and allow for 16, 000 measurements to be performed.
Colorimeter Diagnostics
  • Advanced diagnostics allow for easy troubleshooting of the colorimeter. In the setup menu it is possible to select an option that allows the user to determine the difference between a dark read (LED off) and a blank read (LED on). These Analuzers also automatically performs this check in order to determine when to alert the user that the sample cell needs to be cleaned.
Reagent Reminder
  • The PCA family has a reagent reminder feature to alert the user when the reagents are running low. When the reagents are changed the counter is reset and the meter automatically tracks the number of readings performed.
Amplified pH/Temperature Probe
  • An integrated pt100 temperature sensor allows for automatic temperature compensation of pH measurements and allows for monitoring temperature as well. The built in amplifier and matching pin provides for exceptional performance where other probes fail when placed in line with pumps and motors.
Data Logging
  • The analyzers can store up to 3500 readings (at least 7 days worth of records when set to a a3 minutes sampling interval) that can be reviewed or downloaded to a Windows compatible PC using the HI92500 software and the RS485 serial port. Logged records contain the date time and reading of all parameters measured along with any alarm status.
GLP Data
  • The GLP data allows for the user to review the data and time for the last Chlorine and pH calibration.
Digital RS485 Output
  • The PCA Family has a RS485 digital output that allows for connection to a Windows compatible PC running the HI92500 software. The software allows for remote monitoring, review of logged data, events and errors, and executing setup options.
Two Analog Outputs (PCA340)
  • The PCA340 features two selectable 0-20 or 4-20 mA signal output that are scalable for the transmission of readings to external recording devices. The analog outputs can also be set for dosing and used with dosing pumps that accept a 4-20 mA analog input. The analog outputs can be used for any of the three measured parameters.
Two Dosing Relays
  • The dosing relays of these analyzers can be connected to a pH and/or chlorine dosing pumps. The chlorine relays are proportionally controlled while the pH relay can be set for on/off or proportional control. The proportional controloffers very fine control of doing to prevent any
    overshoot and wastage of chemicals.
Alarm Relay
  • One SPDT alarm relay is provided that can be activated by adjustable upper and lower chlorine, pH and temperature limits.
Error Relay
  • One SPDT error relay is provided and is activated when an error is present including a problem with the colorimeter such as when the reagent counter has reached zero, or when a reading is outside the range for a measured parameter.
Warning Messages
  • Error messages are displayed when the reagents are expired or low and if the colorimeter cell needs to be cleaned.

Specifications

SKU PCA310-01-web
Name Chlorine, pH, ORP, and Temperature Analyzers – PCA300 Series
pH Range (PCA320, PCA330 and PCA340): 0.00 to 14.00 pH
pH Resolution (PCA320, PCA330 and PCA340): 0.01 pH
pH Accuracy (PCA320, PCA330 and PCA340): ±0.05 pH
pH Calibration automatic one or two points; one point process calibration
pH Dosing Relay ON/OFF or proportional, relay or 4-20mA output
pH Dosing Set Point selectable from 0.10 to 2.00 pH
pH Hysteresis Band selectable from 0.05 to 2.00 pH
pH Sampling Rate adjustable from 3 to 120 seconds
ORP Range (PCA330): 0 to 2000 mV
ORP Resolution (PCA330): 1 mV
ORP Accuracy (PCA330): ±1 mV
Temperature Range (PCA320, PCA330 and PCA340): 5.0 to 75.0 °C (41.0 to 167.0 °F)
Temperature Resolution (PCA320, PCA330 and PCA340): 0.1 °C (0.1 °F)
Temperature Accuracy (PCA320, PCA330 and PCA340): ± 0.5 °C (± 1.0 °F)
Free Chlorine Range 0.00 to 5.00 mg/L (ppm)
Free Chlorine Resolution 0.01 mg/L (ppm)
Free Chlorine Accuracy ± 8% or ±0.05 mg/L whichever is greater
Total Chlorine Range 0.00 to 5.00 mg/L (ppm)
Total Chlorine Resolution 0.01 mg/L (ppm)
Total Chlorine Accuracy ± 8% or ±0.05 mg/L whichever is greater
Chlorine Calibration One point process calibration
Chlorine Sampling Rate adjustable from 3 to 90 minutes
Chlorine Dosing Relay proportional relay or 4-20 mA output
Chlorine Dosing Set Point selectable from 0.1 to 5 mg/L (ppm)
Dosing Control SPDT contact with 5A, 230V resistive load
Alarm Relay Set Point SPDT contact with 5A, 230V resistive load
Analog Ouput Signal 0-10 mV, 0-100 mV, 0-1 V, 4-20 mA, 0-20 mA (PCA310, PCA320, PCA330) 4-20 mA, 0-20 mA (PCA340)
Baud Rate 1200; 2400; 4800; 9600 bps
Enclosure NEMA-4X standard, molded fiberglass polyester with transparent Lexan window
Inlet Sample Pressure 0.07 to 4 bar with no external pressure regulator (for pressure exceeding four bar an external pressure regulator is required)
Sample Flow Rate 100 to 300 mL/min
Sample Temperature 5 to 40°C (41 to 104°F)
Sample Inlet/Outlet Connection 12mm (1/2”) male NPT fitting
Drain Connection 10mm (3/8 in.) barb
Logging Memory 3500 log records
Connectivity RS485, galvanic separated
Display character LCD 4 lines x 20 characters (languages: English, Italian, Portuguese, Spanish)
Power Supply 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz; 20 VA
Dimensions 318 x 267 x 159 mm (12.5 x 10.5 x 6.25”)
Weight 5 kg (11 lb.) without reagents

Ordering Info

Each analyzer is supplied complete with: 2 pcs. reagent bottles (1 pc. indicator and 1 pc. buffer solution), 2 pcs. reagent bottle caps, 5 pcs. DPD compound powder, tubing, and instruction manual.

Manuals

Chlorine, pH, ORP, and Temperature Analyzers – PCA300 Series

Bestsellers

Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

491.00 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible
Inquire Now

Boron Chemical Test Kit for Irrigation Water - HI38074

481.00 AED
The HI38074 is a chemical test kit that measures boron in irrigation water by titration with boric acid. The HI38074 is supplied complete with all of the reagents and equipment necessary to perform 100 tests.
  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Manual titration performed with electronic pH meter

Soil Test™ Direct Soil EC Tester - HI98331

391.00 AED
The HI98331 Soil Test™ is a pocket tester specifically designed to directly measure soil conductivity (EC) and temperature for quick and accurate readings. With a compact size, single button operation, and automatic calibration, Soil Test is an excellent choice for taking direct conductivity measurements in soil elimintating the need to create soil slurries. 
  • Waterproof
  • 4.5" Stainless Steel Penetration Electrode
  • Automatic Temperature Compensation

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

788.00 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Back to Top
Whatsapp
Product has been added to your cart