Out of stock

Photometric Probe for Colorimetric Titrations at 470 nm – HI900604

For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900604 photometric electrode for when a color change is still the best solution.

    • High color sensitivity in a compact design
    • Chemically resistant glass-body construction
    • Stable blue LED (470 nm) light source with low drift

1,729.00 AED

Inquire Now
SKU:HI900604

The HI900604 photometric electrode has a blue LED with a wavelength of 470 nm as a light source. This wavelength of light is useful for determining a yellow endpoint when using indicators such asĀ bromophenolĀ blue during a volumetric titration.Ā The HI900604 can be used for a variety of applications, including:

  • Carboxyl end groups in polymersĀ according to ASTM D7409.
HI900604  Photometric Probe Sample cell

LED at 470 nm

HI900604 uses a LED that emits light at 470 nm (blue color). This high quality LED will provide long term use since it takes thousands of hours for the LED intensity to dim naturally.

Reflective Measurement

The HI900604 contains a glass flow through cell, which the sample fills. The LED shines light at 470 nm through the sample, which is reflected back by a platinum mirror sealed in the glass tip of the probe. The fixed path length of the reflective measurement allows for high color sensitivity in a compact design.

Automatic Temperature Compensation

All readings are compensated for the changes in temperature of the sample from 0 to 75ā„ƒ (32 to 167℉) to provide for accurate and repeatable measurements.

 HI900604 Photometric Probe Design

Glass-Body Probe

HI900604 probe has a glass-body that offers excellent chemical resistance against organic solvents. These solvents can be found in samples and can attack different forms of plastics.

Steel Shielding

The electronics of the probe are located in a steel shielding, which is covered byĀ the glass-body.Ā The steel sheilding of the probe also blocks out ambient light and protects against electronic interference.Ā 

12 mm Diameter Probe Body

HI900604 has a probe diameter of 12 mm (1/2″), which is the standard size for most pH/ORP electrodes. The 12 mm probe will fit in most electrode holders.

 HI900603 with HI932 Titration System

BNC Connector

HI900604 has a BNC connector for connecting a pH/mV input of a meter. The mV range for the probe is from 10 to 1100 mV.

PS/2 Mini-DIN Connector

A PS/2 connector is used for supply power to the probe. The HI931and HI932 potentiometric titration systems have a ps/2 power output for the probe to be connected to. The HI900932 is a PS/2 Y-splitter that is also available and allows for multiple probes to use one power source.

LED Calibration Trimmer

Although the LED provides a very long life, it does slowly dim over time. A trimmer located in the head of the probe can be used to adjust the output intensity. This allows the probe to be recalibrated, ensuring accurate measurements.Ā The probe is placed in DI or distilled water and the trimmer adjusted until 1000 mV (100% transmittance) is displayed.

Specifications

SKU HI900604
Name Photometric Probe for Colorimetric Titrations at 470 nm – HI900604
mV Range 10 to 1100 mV
Photometric Probe Wavelength 470 nm
Photometric Probe Light Source LED
Measuring Cycle LED pulsed at 1 kHz
Photometric Probe Light Detector silicon photocell
Temperature Compensation automatic from 0 to 75°C (32 to 167°F)
Body Material glass
Body Length/Overall Length 120 mm / 200 mm
Outer Diameter 12 mm
Connector Type BNC
Power Supply PS/2
Environment 0 to 50°C (32 to 122°F)

Ordering Info

HI900604 photometric probe is delivered in a plastic case and is supplied with a trimmer tool, quality certificate, and instruction manual.

Manuals

Photometric Probe for Colorimetric Titrations at 470 nm – HI900604

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart