-
-
-
-
Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)
14,584.00 AED4,125.60 AED -
COD Test Tube Heater - HI839800 (230V)
14,600.00 AED4,140.00 AED
Out of stock
pH and Free and Total Chlorine Portable Photometer – HI96710
The HI96710 is no longer available.
Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.
Both meters use the same reagents.
908.00 AED
Inquire NowThe HI96710 portable photometer is for the measurement of pH and free and total chlorine. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
*Reagents ordered separately

CAL Check™ standards with certificate
The CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function. Individual sets of CAL Check™standards are available for each parameter found in the HI96710:
- pH: HI96710-11
- Free Chlorine: HI96701-11
- Total Chlorine: HI96711-11
Supplied with Certificate of Analysis
- Lot number
- Expiration date
- Standard value @ 25 ℃
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage

Specifications
| SKU | HI96710-web |
| Name | pH and Free and Total Chlorine Portable Photometer – HI96710 |
| pH Range | 6.5 to 8.5 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.1 |
| pH Method | phenol red method |
| Free Chlorine Range | 0.00 to 5.00 mg/L (ppm) |
| Free Chlorine Resolution | 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L |
| Free Chlorine Accuracy | ±0.03 mg/L (ppm) ±3% of reading |
| Total Chlorine Range | 0.00 to 5.00 mg/L (ppm) |
| Total Chlorine Resolution | 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L |
| Total Chlorine Accuracy | ±0.03 mg/L (ppm) ±3% of reading |
| Chlorine Method | adaptation of the USEPA method 330.5 |
| Photometer/Colorimeter Light Source | tungsten lamp |
| Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
| Battery Type/Life | 9V battery |
| Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Weight | 360g (12.7oz.) |
| Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Info
HI96710 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.










