In stock

opdo Waterproof Optical Dissolved Oxygen Meter – HI98198

HI98198 portable Optical DO (opdo) meter uses a luminescent optical method for the measurement of dissolved oxygen in water and wastewater. This professional, waterproof meter complies with IP67 standards and measures DO, barometric pressure, BOD and temperature. The HI98198 is supplied complete with all accessories including probe, smartcap sensor with built in RFID, and a rugged carrying case. 

HI98198 Dissolved Oxygen Meter has many advanatages over other Galvanic and Polarographic Dissoved Oxygen Meters. This meter uses HI764113 Rugged Optical Dissolved Oxygen Probe for Dissolved Oxygen measurement which has following benefits. 

  • No membranes or electrolyte
  • No flow dependence or minimum flow rate
  • Fast and stable readings
  • Minimal maintenance

Original price was: 7,250.00 AED.Current price is: 6,600.00 AED.

Estimated delivery: 15 - 16 January

SKU:HI98198
Optical Dissolved Oxygen Meter

HI98198 measures dissolved oxygen levels in water using enhanced optical dissolved oxygen technology to ensure high levels of accuracy. With built-in methods and calculations for the measurement of Biological Oxygen Demand (BOD), Oxygen Uptake Rate (OUR), and Specific Oxygen Uptake Rate (SOUR), there is no need for manual conversions.

Increased Traceabilty

Ensure that your data can be trusted with GLP data. Accessible by a fixed dedicated key, this data includes date, time, pressure, calibrated value, temperature and salinity value of the last calibration.

Versatile Data Logging

The HI98198’s log-on-demand feature allows you to store up to 4000 readings. The AutoEnd button can be used during measurement to hold the first stable reading on the display automatically.

Focus on What Matters

When you put on a new cap, your meter will detect and initialize it. It will remind you when your cap needs to be replaced, is damaged, or is missing, giving you one less thing to worry about.

Quick Connect Probe

Superior Field Usability

An IP67-rated, waterproof meter means that bad weather, splashes, and dust won’t stop you from taking important measurements. The HI98198 is built to withstand immersion in water of 1m for up to 30 minutes. A large display and back light feature ensure that all of your important information is easily visible, no matter the amount of light.

Universal Port

The ultra-versatile USB-C port integrates seamless transfer of data. There is no need for software- simply connect a USB-C and send your data as a .csv to a memory stick, computer, or android device.

Quick Connect Probe

The Quick Connect fitting is designed for quick and easy installation of the DO probe. A watertight connection without threads make attaching and removing the probe simple.

HI764113 Rugged Optical DO Probe

HI764113 Rugged Optical DO Probe for Fresh and Saltwater Applications

Built Strong

A robust ABS body and stainless steel protective guard ensure durability when measuring in tough environments. With an IP68 rating, this probe is totally sealed against water and dust.

Professional Level Performance

The domed cap repels bubbles for better measurement sensitivity, providing a fast response time.

Minimize Hassle

With no additional membranes to change and no electrolyte needed, the opdo probe is ready to work right when you need it.

Smart Cap Technology

Smart Cap Technology

Automatic Cap Recognition

Hanna’s Smart Caps feature a built-in RFID reader that is able to store important data, including manufacture date and first-use date for increased traceabilty.

Longer Life

Smart Caps last one year from the date of first use. Your meter will automatically count down from initialization and will have your meter remind you when it has expired with an on-screen message.

Aligned Right Every Time

An alignment key ensures that your Smart Cap is on correctly every time.

HI98198 Optical Dissolved Oxygen Box

We believe that buying a meter should be simple. Your Optical Dissolved Oxygen Meter is equipped with everything you need for successful testing right out of the box.

Zero Oxygen Calibration Solution

When performing a DO calibration, it is important that the correct standards are used. We include some starter solution to get you going. HI7040L is a bi-component zero oxygen solution designed so you can quickly calibrate to 0% oxygen concentration.

Accessories

Having the accessories you need on hand makes testing a simple process. The included calibration vessel and beakers fit snug in the rugged carrying case and a USB cable lets you transfer your data with ease.

Complete Package

Your meter, probe, and accessories are all neatly packaged in a rugged carrying case to ensure that you have everything you need for on-the-go field testing.

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7010/1L pH 10.01 Calibration Solution (1 L)

    77.00 AED
    HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
    • Solution dyed violet for easy pH buffer value identification
    • Accuracy of ±0.01 pH @ 25℃
    • Temperature chart of the actual pH value at various temperatures printed on each bottle

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass
    Back to Top
    Whatsapp
    Product has been added to your cart