Out of stock

Low Range Titrant for Titratable Alkalinity in Water Mini Titrator – HI84431-50U

The HI84431 utilizes two different titrant solutions to cover the entire measurement range of alkalinity in water. The titrants used have differing concentrations that are appropriate for each measurement range. Low range measurements use the HI84431-50 low range (10 to 500 mg/L as CaCO3) titrant. The titrant solution for the HI84431 mini titrator comes pre-standardized, making titrations fast, accurate, and simple.

  • Pre-standardized titrant
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal to ensure quality

97.00 AED

Estimated delivery: 25 - 26 April

Inquire Now
SKU:HI84431-50U

The HI84431-50 is a 100 mL bottle of acidic titrant solution that is used for low range (10 to 500 mg/L as CaCO3) determination of alkalinity in water.

Water alkalinity is an expression of a water’s acid-neutralizing capacity and it is determined by titration with standard acidic solutions. Alkalinity is an important parameter for control and treatment of potable water and wastewater because it indicates the buffering capacity of water, or the ability to resist a pH change. The ability to resist large swings in pH results primarily from the presence of bicarbonates and carbonates. A low water alkalinity signifies that the water is susceptible to pH change, while a high alkalinity indicates that water is able to resist a major change of pH.

Alkalinity can be used to estimate levels of hardness or to determine the corrosive capacity of water. Alkalinity of surface water, quantified by mg/L as CaCO3 or meq/L, may be caused by carbonates, bicarbonates, hydroxides, phosphates, borates, silicates, or organic acid salts. Conventionally, the water alkalinity is approximated as sum of components. Three types of alkalinities exist together to form total alkalinity (TA):

TA = OH + CO32 + HCO3

OH = hydroxide alkalinity

CO32 = carbonate alkalinity

HCO3 = bicarbonate alkalinity

TA = total alkalinity

Different tests can be performed to determine the quantity of different alkalinities present. According to the Standard Methods of Water and Wastewater Analysis, there are two options to determine water alkalinity: 1) Strong alkalinity determination by titration of the water sample with strong acid solution to 8.3 pH (known as phenolphthalein alkalinity), or 2) Total alkalinity determination by titration of the water sample with strong acid solution to 4.5 pH (known as bromcresol green alkalinity).

Replacement reagents required to operate the HI84431:

Low Range – 10 to 500 mg/L as CaCO3High Range – 400 to 4000 mg/L as CaCO3
Pump calibration standardHI84431-55MHI84431-55M
Titrant solutionHI84431-50HI84431-51

Specifications

SKU HI84431-50U
Name Low Range Titrant for Titratable Alkalinity in Water Mini Titrator – HI84431-50U
Description Low Range Titrant for Titratable Alkalinity in Water Mini Titrator
Package bottle
Quantity 1
Size 100 mL

Manuals

Low Range Titrant for Titratable Alkalinity in Water Mini Titrator – HI84431-50U

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

    32.00 AED
    The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high purity chemicals
    • Marked with expiration date and lot number for traceability
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Back to Top
    Whatsapp
    Product has been added to your cart