Out of stock

Leather and Paper pH Portable Meter – HI99171

The Hanna Instruments HI99171 is a durable, waterproof, and portable pH and temperature meter designed specifically for leather and paper analysis. Automatic calibration is performed at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature variations.The HI99171 uses the HI14143 glass body, amplified pH electrode that offers numerous features that improve pH testing for surface measurements. The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.

  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof

Original price was: 1,929.00 AED.Current price is: 1,912.00 AED.

Inquire Now
SKU:HI99171
pH measurement of paper, leather, and other surfaces are important during manufacturing and final product stages. In the paper industry, a pH measurement indicates the chemical stability and permanence of a paper. It is desirable to manufacture paper that has a neutral or slightly basic pH to aid in the preservation of important documents, publications, and artworks. An acid-free or alkaline paper is able to absorb damaging acid compounds that are naturally formed through aging.pH of paper and cartons is also important in the food industry. Food packaging often incorporates antimicrobial agents to inhibit microbial activity during distribution and storage conditions. The activity of antimicrobial agents can quickly change with a variation in pH. pH compatibility tests consider food composition, chemistry of the antimicrobial agents used, and packaging material.In leather making, tanning is one of the most chemically complex steps. Generally, tanning creates a leather product that is more breathable, flexible, and suitable for use in handbags, luggage, garments, and a variety of commercial items. Tanning is performed by a vegetable method or chrome method; chrome-tanned leather requires the addition of chromium salts and a basic component to raise the pH. The pH of the liquors used in the leather making process and the pH of the final leather product directly affect characteristics such as firmness, heat resistance, and durability.
The HI99171 uses the HI14143 amplified pH electrode with glass body. This specialized electrode offers numerous features that improve surface pH testing. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The probe’s flat sensing tip provides optimal surface contact with samples.An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Poor contact between the junction and sample will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.The flat tip of the HI14143 provides optimal surface contact between the sample and the junction. The HI14143 features an open junction design which utilizes a viscolene reference electrolyte that comes into direct contact with the sample, providing accurate, stable readings.
HI1414D
Glass Body

Glass BodyThe glass body of the HI14143 is chemically resistant and quick to reach thermal equilibrium, allowing for a faster, more stable response on a wide variety of surfaces.

Flat Tip

Flat TipThe flat tip sensing bulb allows for the direct surface measurement of a sample. The versatility of this tip shape allows pH measurement of samples ranging from leather and paper to cartons.

ATC

Open Junction ReferenceThe open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.

ATC

Built-In Temperature SensorErrors in calibration and measurement are eliminated with the Automatic Temperature Compensation provided by the integrated temperature sensor.

Features at-a-glance

 Waterproof – The HI99171 is a waterproof meter rated IP67 for immersion in up to one meter of water for 30 minutes.Automatic Calibration – One or two-point calibration is automatic to two selectable buffer sets.Automatic Temperature Compensation – An integrated temperature sensor allows for automatic temperature compensation of pH measurements.Sensor Check – Using the pH‐mV range the user can check the sensor status by reading the mV reading in fresh buffers. At room temperature (25 ā„ƒ/77℉) the reading should be ±30 mV in pH 7.01 and greater than 150 mV difference between pH 7.01 and 4.01.Multi-Level LCD Display – The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and probe condition.Probe Condition Indicator – The probe condition indicator is based on the offset and slope characteristic of the electrode. There are 5 bars ranging from all 5 indicating the probe is in excellent condition and 1 bar indicating the probe should be cleaned or replaced.Battery Error Prevention System – The meter will automatically shut off if there isn’t enough power to obtain an accurate measurement.Battery Life Indicator – The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

Specifications

SKU HI99171
Name Leather and Paper pH Portable Meter – HI99171
pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic, at one or two points with two sets of buffers (standard 4.01, 7.01,10.01 or NIST 4.01, 6.86, 9.18)
pH Temperature Compensation automatic from -5.0 to 105.0ĀŗC (23 to 221ĀŗF)
pH CAL Check (electrode diagnostics) probe condition indicator
pH Sensor Check yes
mV Range ±825 mV (pH‐mV)
mV Resolution 1 mV (pH‐mV)
mV Accuracy ±1 mV (pH‐mV)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
pH Electrode HI14143 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Automatic Shut-Off user selectable: after 8 min, 60 min or disabled
Battery Type/Life 1.5V (3) AAA / approximately 1400 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2ā€)
Weight 196 g (6.91 oz.)

Ordering Info

HI99171 is supplied with HI14143 flat tipped pH/temperature probe, HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700680 electrode cleaning solution for ink stains sachets (2 x 20 mL), HI70960 conductive electrolyte solution for pH measurement (30 mL), 100 mL beaker, batteries, calibration certificates for both the meter and probe, instructions and rugged thermoformed carrying case.

Manuals

Leather and Paper pH Portable Meter – HI99171

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

Original price was: 638.00 AED.Current price is: 631.00 AED.
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

84 µS/cm Conductivity Standard (1 L) – HI7033/1L

Original price was: 100.00 AED.Current price is: 83.00 AED.
HI7033/1L is a premium quality 84 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Digital Refractometer for Brix Analysis in Foods - HI96801

Original price was: 869.00 AED.Current price is: 860.00 AED.
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

GroLine pH 7.01 Calibration Buffer (500mL) - HI7007-050

61.00 AED
HI7007-050 is a high quality pH 7.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Refillable Combination pH Electrode with BNC Connector - HI1131B

Original price was: 640.00 AED.Current price is: 601.00 AED.
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

COD Test Tube Heater - HI839800 (230V)

4,600.00 AED
The HI839800 COD Test Tube Heater is an easy to use thermoreactor constructed of durable materials. The aluminum block incorporates a 25 vial capacity and a well for a reference temperature probe. Its well-marked user interface provides intuitive operation, equipped with two arrows to set the built-in timer and a temperature button with two predefined temperature settings: 150ā„ƒ and 105ā„ƒ. Additional features include status indicator lights, a thermal fuse to prevent overheating, and continuous LCD display.
  • Low and high temperature alerts
  • Built-in countdown timer
  • Status indicator lights

Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)

Original price was: 4,584.00 AED.Current price is: 4,541.00 AED.
HI83314 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterWastewater Treatment Digestion ParametersMeasures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus
Back to Top
Whatsapp
Product has been added to your cart