Out of stock

Infrared and Contact Thermometer for the Food Industry – HI99556

The HI99556 is an infrared and contact thermometer designed to measure both surface and core temperatures for the food industry. With an external probe, a quick, one-second infrared response time, a HOLD function, and battery life indicator, this thermometer is an ideal solution for temperature measurements in the food industry. There are two models of the HI99556 thermometers, each offering a different measurement range, resolution and option for an external probe. The HI99556-00 covers a temperature range from -10 to 300℃ with 1℃ resolution, while the HI99556-10 covers a temperature range from -20.0 to 199.9℃ with 0.1℃ resolution. The HI765PW probe offers core measurements that cover a temperature range from 40 to 150℃.

  • ±2% (of reading) or ±2℃ Infrared Accuracy
  • ±0.5℃ (+1℃ outside range) Probe Accuracy
  • IR/Contact Mode
  • HOLD Function

Inquire Now
SKU:HI99556

The Infrared and Contact Thermometer for the Food Industry – HI99556 is a durable meter that can be used throughout the food industry. The HI99556 offers an external temperature probe and features such as a quick, one-second response time, HOLD function, and Hanna’s Battery Error Prevention System (BEPS) that will shut the meter off when the battery power is too low for an accurate measurement.

As an infrared thermometer, the non-intrusive nature of the HI99556 is particularly attractive in the food industry since it translates itself into substantial savings by leaving products intact, especially those sealed or pre-wrapped. This type of non-intrusive measurement is also useful when the surface temperature is high, for difficult-to-reach places, or hygiene requirements must be followed.

As a contact thermometer with the HI765PW external probe, the HI99556 is able to check the internal temperature in addition to the surface measurement. By simply attaching the NTC thermistor probe, the meter becomes a convenient, 2-in-1 infrared-thermistor thermometer.

Features at-a-glance

HI765PW Thermistor Probe – The HI99556 is supplied with the HI765PW NTC thermistor probe. The thermometer accepts this external NTC thermistor temperature probe to allow for core measurements in addition to surface measurements. Measurement selection between the external probe and infrared sensor is simple through a dedicated button on the face of the meter.

℃ Readout – Measurements are displayed in degrees Celsius on the clear, easy to read LCD display.

Optic Coefficient – The optic coefficient is the distance between the sensor and the measured object is an important factor in infrared measurement. With a 3:1 relationship between the distance and object area, the HI99556 can measure an area with a diameter that is one-third of the distance between the sensor and the object.

Fixed Emissivity – Emissivity is the ratio of infrared radiation emitted by an object to that emitted by a perfect black body at the same temperature. The HI99556 was designed to measure the temperature of objects with an emissivity of 0.95, which is characteristic of most objects and surfaces being measured.

HOLD Function – The HOLD function freezes the display to allow the user time to record readings when taken in hard to reach places.

Battery Error Prevention System (BEPS) – The Battery Error Prevention System will shut the meter off when the battery power is too low for an accurate measurement.

Low Battery Indicator – When the battery level is below 10%, a warning symbol will blink to indicate low battery condition.

Specifications

SKU HI99556-web
Name Infrared and Contact Thermometer for the Food Industry – HI99556
Temperature Range -10 to 300°C (HI99556-00); -20.0 to 199.9°C (HI99556-10)
Temperature Resolution 1°C (HI99556-00); 0.1°C (HI99556-10)
Temperature Accuracy ±2% of reading or ±2°C
Thermistor Temperature Range -40 to 150°C (HI99556-00); -40.0 to 150.0°C (HI99556-10)
Thermistor Temperature Resolution 1°C (HI99556-00); 0.1°C (HI99556-10)
Thermistor Temperature Accuracy ±0.5°C (-20 to 120°C); ±0.5°C +1% reading (outside)
Temperature Probe HI765PW general purpose/penetration, stainless steel thermistor temperature probe with white handle and 1 m (3.3’) cable (included)
Battery Type/Life 9V / approximately 150 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 143 x 80 x 38 mm (5.6 x 3.2 x 1.5”)
Weight 320 g (11.3 oz)

Ordering Info

HI99556

Manuals

Infrared and Contact Thermometer for the Food Industry – HI99556

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Back to Top
    Whatsapp
    Product has been added to your cart