Out of stock

HI5321 Research Grade EC/TDS Meter with USP (230V)

HI-5321 can be used to perform all 3 stages of USP method required for conductivity measurement of pure and ultra-pure water.

3,839.00 AED

Inquire Now
SKU:HI5321-02

HI-5321 can be used to perform all 3 stages of USP <645> method required for conductivity measurement of pure and ultra-pure water. The instrument provides clear directions on how to perform each testing stage and automatically monitors the temperature, conductivity and stability during testing and determines whether a sample is within USP limits.

This instrument is equipped with auto standard recognition and can support custom calibration solutions. Up to a four point calibration can be obtained for enhanced accuracy over an extended measuring range.

The enhanced warning system is in place to alert users when measuring outside the calibration range. This system will also remind the user when a new calibration is due.

Features also include real-time graphic displays and on-screen GLP data. On-board contextual help can be accessed from any mode via the HELP button.

Up to 10 profiles can be saved and recalled eliminating the need to reconfigure each time when a different electrode is used.

Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots with 10,000 records per lot can be stored for automatic or manual modes along with up to 200 USP reports.

All features are available in English, Italian, Portuguese and Spanish. Connect to a PC via the USB or RS232 ports with the use of HI-92000 Windows? compatible software.

Ideal for

  • pharmaceutical advanced research
  • vaccine development
  • environmental laboratories

Supplied with:

  • HI-76312 conductivity probe
  • HI-76404N electrode holder
  • 12VDC power adapter
  • Instruction manual

Specifications

SKUHI5321-02
EC –
Range
0.000 to 9.999 µS/cm; 10.00 to
99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99
mS/cm; 100 0 to 1000.0 mS/cm absolute
EC*
?Resolution0.001µS/cm;
0.01µS/cm; 0.1µS/cm; 0.001mS/cm; 0.01mS/cm; 0.1mS/cm
?Accuracy±1%
of reading (±0.01µS/cm)
?Cell
Constant
0.0500 to
200.00
?Cell
Type
4
cells
?Calibrationautomatic
standard recognition, user standard single point/multi-point calibration
?Calibration
Reminder
yes
?
Temperature Coefficient
0.00 to
10.00%/°C
? Temperature
Compensation
disabled, linear and
non-linear (natural
water)
?Reference
Temperature
5.0 to
30.0°C
?Profilesup
to 10, 5 each channel
?USP
Compliant
yes
TDS
– Range
0.000 to 9.999 ppm; 10.00 to
99.99 ppm; 100.0 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to
400.0 ppt actual TDS (with 1.00 factor)
?Resolution0.001
ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt; 0.001 ppm; 0.001 ppm;
0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1
ppt
?Accuracy±1%
of reading (±0.01 ppm)
Resistivity –
Range
1.0 to 99.9 ? • cm; 100 to 999
? •cm; 1.00 to 9.99 K ? •cm; 10.0 to 99.9 K ? • cm; 100 to 999 K ? • cm; 1.00
to 9.99 M ? •cm; 10.0 to 100.0 M ? •
cm
?Resolution0.1
? • cm; 1 ? • cm; 0.01 K ? • cm; 0.1 K ? • cm; 1 K ? • cm; 0.01 M ? • cm; 0.1
M ? • cm
?Accuracy±2%
of reading (± 1 ? • cm)
Salinity –
Range
practical scale: 0.00 to 42.00
psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0%
NaCl
?
Resolution
0.01 for practical
scale/natural sea water scale; 0.1% for percent scale
?Accuracy±1%
of reading
?
Calibration
percent scale-one point
(with HI-7037 standard)
Temperature
– Range
-20.0 to
120°C
?Resolution0.1°C
?Accuracy±0.2°C
(without probe)
Temperature
Compensation
Linear and non-linear
(natural water)
EC ProbeHI-76312
platinum, four ring EC/TDS probe with 1m cable
(included)
GLPcell
constant, reference temperature/coefficient, calibration points, calibration
time stamp, probe offset for
conductivity
Loggingrecord:
100,000 data point storage/channel, up to 100 lots with max, 50,000 records-lot;
Interval: settable between 1 second and max log time of
180
minutes;
Displaycolour
graphic LCD with on-screen help, graphing, and custom colour
configuration
PC
Connection
USB
Power
Supply
12VDC adapter
(included)
Environment0
to 50°C; RH max 95%
non-condensing
Dimensions/Weight160
x 231 x 94 mm / 1.2kg

Bestsellers

HI731336N Caps for Glass Cuvette Used with HI977 Series Portable Photometers (4 pcs)

59.00 AED
The HI731336N are the replacement caps that screw on the glass cuvettes used with the HI977xx series portable photometers. Each cap has a locking indexing tab that ensures the cuvette is inserted into the photometer in the same position. The caps are also used to block any light that would interfere with the optically based measurement. The HI731336N includes 4 caps.
  • Locking index tab for proper alignment in the photometer
  • Light blocking to prevent stray light from entering

Silicon oil for turbidity meter

94.00 AED
HI98703-58 silicone oil is for use with Hanna's line of turbidity meters. This easy to use dropper bottle ensures the glass cuvette used for turbidimetric measurements remains free from imperfections and scratches, helping to provide accurate readings every time.
  • Convenient dropper bottle
  • Marked with lot number and expiration date
  • Light tight bottle

1 mL Graduated Syringe (6 pcs)

59.00 AED
HI740143 is a package of 6 graduated syringes for accurate dosing reagents for chemical test kits and photometers.
  • 1mL capacity
  • 6 syringes per set
  • Ideal for for accurate reagent dosing for CTK and photometers

Replacement temperature probe for HI5XXX research grade benchtops

309.00 AED
Replacement temperature probe for HI5XXX research grade benchtops
Inquire Now

HI5321 Research Grade EC/TDS Meter with USP (230V)

3,839.00 AED
HI-5321 can be used to perform all 3 stages of USP method required for conductivity measurement of pure and ultra-pure water.
Inquire Now

Mini-Fertilizer Injection System

The HI2500 Mini-Fertilizer Injection System precisely monitors and controls fertilizer concentrations (EC, TDS, or ORP) and pH for specialized hydroponics and small greenhouse applications.
  • Fully assembled for easy installation.
  • Probes are able to hang in a reservoir or be kept on an electrode holder.
  • Perfect system for the small to medium size grower.
  • Plastic Pipette Tip for Graduated Syringe (6 pcs)

    71.00 AED
    The HI740144P is a 6 piece set of 1mL plastic syringe tips that can be used with the HI740143 Graduated Syringe. The syringe and disposable tips are designed to measure and transfer fixed volumes of liquids that require precise dosing.
    • Durable plastic
    • Disposable
    • For use with HI740143 Graduated Syringe