Out of stock

HI5321 Research Grade EC/TDS Meter with USP (230V)

HI-5321 can be used to perform all 3 stages of USP method required for conductivity measurement of pure and ultra-pure water.

3,839.00 AED

Estimated delivery: 30 - 31 March

Inquire Now
SKU:HI5321-02

HI-5321 can be used to perform all 3 stages of USP <645> method required for conductivity measurement of pure and ultra-pure water. The instrument provides clear directions on how to perform each testing stage and automatically monitors the temperature, conductivity and stability during testing and determines whether a sample is within USP limits.

This instrument is equipped with auto standard recognition and can support custom calibration solutions. Up to a four point calibration can be obtained for enhanced accuracy over an extended measuring range.

The enhanced warning system is in place to alert users when measuring outside the calibration range. This system will also remind the user when a new calibration is due.

Features also include real-time graphic displays and on-screen GLP data. On-board contextual help can be accessed from any mode via the HELP button.

Up to 10 profiles can be saved and recalled eliminating the need to reconfigure each time when a different electrode is used.

Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots with 10,000 records per lot can be stored for automatic or manual modes along with up to 200 USP reports.

All features are available in English, Italian, Portuguese and Spanish. Connect to a PC via the USB or RS232 ports with the use of HI-92000 Windows? compatible software.

Ideal for

  • pharmaceutical advanced research
  • vaccine development
  • environmental laboratories

Supplied with:

  • HI-76312 conductivity probe
  • HI-76404N electrode holder
  • 12VDC power adapter
  • Instruction manual

Specifications

SKUHI5321-02
EC –
Range
0.000 to 9.999 µS/cm; 10.00 to
99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99
mS/cm; 100 0 to 1000.0 mS/cm absolute
EC*
?Resolution0.001µS/cm;
0.01µS/cm; 0.1µS/cm; 0.001mS/cm; 0.01mS/cm; 0.1mS/cm
?Accuracy±1%
of reading (±0.01µS/cm)
?Cell
Constant
0.0500 to
200.00
?Cell
Type
4
cells
?Calibrationautomatic
standard recognition, user standard single point/multi-point calibration
?Calibration
Reminder
yes
?
Temperature Coefficient
0.00 to
10.00%/°C
? Temperature
Compensation
disabled, linear and
non-linear (natural
water)
?Reference
Temperature
5.0 to
30.0°C
?Profilesup
to 10, 5 each channel
?USP
Compliant
yes
TDS
– Range
0.000 to 9.999 ppm; 10.00 to
99.99 ppm; 100.0 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to
400.0 ppt actual TDS (with 1.00 factor)
?Resolution0.001
ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt; 0.001 ppm; 0.001 ppm;
0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1
ppt
?Accuracy±1%
of reading (±0.01 ppm)
Resistivity –
Range
1.0 to 99.9 ? • cm; 100 to 999
? •cm; 1.00 to 9.99 K ? •cm; 10.0 to 99.9 K ? • cm; 100 to 999 K ? • cm; 1.00
to 9.99 M ? •cm; 10.0 to 100.0 M ? •
cm
?Resolution0.1
? • cm; 1 ? • cm; 0.01 K ? • cm; 0.1 K ? • cm; 1 K ? • cm; 0.01 M ? • cm; 0.1
M ? • cm
?Accuracy±2%
of reading (± 1 ? • cm)
Salinity –
Range
practical scale: 0.00 to 42.00
psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0%
NaCl
?
Resolution
0.01 for practical
scale/natural sea water scale; 0.1% for percent scale
?Accuracy±1%
of reading
?
Calibration
percent scale-one point
(with HI-7037 standard)
Temperature
– Range
-20.0 to
120°C
?Resolution0.1°C
?Accuracy±0.2°C
(without probe)
Temperature
Compensation
Linear and non-linear
(natural water)
EC ProbeHI-76312
platinum, four ring EC/TDS probe with 1m cable
(included)
GLPcell
constant, reference temperature/coefficient, calibration points, calibration
time stamp, probe offset for
conductivity
Loggingrecord:
100,000 data point storage/channel, up to 100 lots with max, 50,000 records-lot;
Interval: settable between 1 second and max log time of
180
minutes;
Displaycolour
graphic LCD with on-screen help, graphing, and custom colour
configuration
PC
Connection
USB
Power
Supply
12VDC adapter
(included)
Environment0
to 50°C; RH max 95%
non-condensing
Dimensions/Weight160
x 231 x 94 mm / 1.2kg

Bestsellers

Inquire Now

HI740034P Cap for 100mL Plastic Beaker (10 pcs)

71.00 AED
The HI740034P is the matching set of plastic caps for use with the HI740036P plastic beakers used with Hanna test kits and various meters.
  • Durable plastic
  • Set contains 10 pieces
  • For use with HI740036P plastic beakers
Inquire Now

Stainless Steel Temperature Probe

321.00 AED
The HI7662 is a stainless steel temperature probe with a 1 m cable length that allows for temperature compensated measurements on compatible Hanna meters.
  • AISI 316 stainless steel
  • NTC thermistor
  • Wide measurement range
Inquire Now

HI2002/5 Standard Model ORP/PT Electrode

772.00 AED
HI-1000 and HI-2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quickly and easily. Models with 3 or 5 metre cables are available.

1 mL Graduated Syringe (10 pcs)

71.00 AED
HI740142P is a package of 10 graduated syringes for accurate dosing reagents for chemical test kits and photometers.
  • 1mL capacity
  • 10 syringes per set
  • Ideal for for accurate reagent dosing for CTK and photometers

Replacement temperature probe for HI931& HI932 titrators

309.00 AED
Replacement temperature probe for HI931& HI932 titrators

HI2003/5 Standard Model ORP/PT Electrode

800.00 AED
HI-1000 and HI-2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quickly and easily. Models with 3 or 5 metre cables are available.
Back to Top
Whatsapp
Product has been added to your cart