Out of stock

HALO Bluetooth® pH Electrode for Wine – HI10482

The HI10482 HALO is a Bluetooth Smart (Bluetooth 4.0) pH and temperature electrode with Hanna’s Clogging Prevention System (CPS).

This electrode has a unique ground glass junction coupled with a PTFE sleeve to prevent particulates within a sample from clogging the junction. In addition to the specialized junction, the HI10482’s glass body and spherical sensing bulb make it ideal for use in a wide variety of applications. All readings are transmitted directly to the HI2202 edgeblu or a compatible Apple or Android device running the Hanna Lab App.

Since the features of the HI10482 HALO electrode are of great benefit to winemakers, the average pH of wine has influenced the choice of calibration buffers when paired with a compatible meter. Generally, a pH between 3 and 4 is optimal for most wines. To increase accuracy and ensure the expected readings are bracketed between the calibration points, pH 3.00 calibration buffer is displayed in lieu of pH 4.01 buffer when this application-specific HALO is connected to the Hanna Lab App.

One Press Connect

Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology.

activity indicator

Status Indicator

Visible from a distance, the LED “halo” light flashes to indicate the status of the probe.

replaceable battery

Easy-to-Replace battery

The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.

1,007.00 AED

Inquire Now
SKU:HI10482

Download the FREE app and try before you buy!
Download Hanna Lab app Download Hanna Lab app

HALOTM - pH Probe with Bluetooth® Smart Technology

The HI10482 HALO is a revolutionary pH electrode that incorporates Bluetooth® Smart (Bluetooth 4.0) wireless technology with an application-specific design. This double junction electrode has many features that make it ideal for use throughout a wide variety of industries, including wine. These features include General Purpose (GP) glass, spheric bulb design, integrated temperature sensor, glass body, and is refillable with 3.5M KCl fill solution electrolyte.

HI10482GPglass

General Purpose Glass Formulation

General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The HI10482 is suitable to use with wine samples that measure from 0 to 80℃ (32 to 176℉).

HI10482GPglass

Spheric Glass Tip

The spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions, such as wine, due to its large surface area. Other tip shapes include conic for penetration and flat tip for surface measurements.

HI10482tempsensor

Built-In Temperature Sensor

HI10482 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential as predicted by the Nernst equation. By having an accurate reading it is possible to provide a temperature compensated reading. Having a built in temperature sensor is important in wine since the measured pH values are more than 3 pH units away from the isopotential point. The further away from the isopoetntail point the greater the influence that temperature has on the observed reading.

HI10482glassbody

Glass Body

The glass body of the HI10482 is ideal for wine analysis use. Glass is resistant to many harsh chemicals and is easy to clean wine stains from. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent, so the faster thermal equilibrium is reached, the steadier the reference potential.

ph meter electrode for wine analysis
HI10482sleeve

Movable CPS Sleeve Junction

Clogging Prevention System (CPS) technology is an innovation for the improvement of pH measurements in wine juice and must samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples with high solids content. When the junction is clogged, the electrode does not function properly and erratic readings are the result. The CPS technology utilizes ground glass junction coupled with a PTFE sleeve to prevent clogging. The ground glass allows proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes. When the electrode becomes fouled the PTFE sleeve can be moved to clean the ground glass surface rejuvenating the junction and extending the probe life.

Hanna Lab App

HALO pH electrodes can connect with HI2202 edgeblu meter or a compatible Apple or Android device running the Hanna Lab App.

HALOTM - pH Probe with Bluetooth Smart Technology

The Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration, measurement, data logging, graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display, with tabulated data, or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.

calibration

Five-Point Calibration

The Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0℃ during calibration. To increase measurement accuracy and bracket expected readings between the calibration points, pH 3.00 calibration buffer is displayed in lieu of pH 4.01 buffer when this application-specific HALO is connected to the Hanna Lab App.

photo2

Real-Time Data

Display of pH and temperature updated every second. Readings are automatically saved to a history file every hour, limited only by the available memory on the device.

photo3

Fluid, Dynamic Graphing

Measurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.

HALO pH electrode for wine with bluetooth

Connecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.

appenabledthm

GLP (Good Laboratory Practice)

Displays date and time of current calibration, probe offset, and average slope, along with calibrated buffers, mV values, temperature and slopes between each buffer.

halo alarm

Calibration Reminder & Measurement Alarms

The Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.

halo share

Log & Share Data

Saved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.

halo help

Help & Tutorials

Demo probe mode helps you explore features of the Hanna Lab App. General app information, General HALO information, pH tutorial, maintenance tutorial, and contact information are available in help.

Hanna Lab App Features/Benefits:

Connects to HALO electrodes via Bluetooth Smart Technology (Bluetooth 4.0)

Up to five-point pH calibration with seven standard pH buffers available Calibration reminder

  • Alerts you when HALO needs calibration
  • Appropriate preprogrammed calibration buffer set for application specific Halo pH electrodes

Real-time data

  • Displays pH and temperature updated every second

Basic GLP

  • Displays date and time of current calibration along with probe offset and average slope

Full GLP

  • Displays date and time of current calibration, probe offset and average slope along with calibrated buffers, mV values, temperature and slopes between each buffer

Fluid, dynamic graphing

  • Measurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing

Measurement alarms

  • Alerts you if the measurement threshold is exceeded

One button sample tagging

  • Pressing either the probe icon in the Hanna Lab App or button on the HALO pH probe will tag sample data for easy reference

Data logging with custom annotations

  • Saved log files may be annotated with measurement  specific  information
  • Data is autosaved every hour

Four ways to save and share data:

  • All data since last autosave
  • Annotations only
  • All data within a timed interval
  • Annotations only within a timed interval

Share data via email in CSV format

Help and tutorials:

  • Demo probe mode to help explore features of the Hanna Lab App
  • General app information
  • General HALO information
  • pH tutorial
  • Maintenance tutorial
  • Contact information

Compatibility:

HALO pH electrodes are compatible with HI2202 edgeblu meter and the following devices:

Android
Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.

iOS
iPad (3rd generation or newer)
iPhone (4S or newer)
iPod Touch (5th generation or newer)

Information about which products have Bluetooth Smart Technology (4.0), also known as low energy (LE), can be found here.

Video

40e78888f8bf4b55edc940174475d319898347de

Specifications

SKU HI10482
Name HALO Bluetooth® pH Electrode for Wine – HI10482
Measurement Range pH: 0 to 12
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate open, CPS technology
Refill Electrolyte 3.5M KCl
Body Material glass
Tip / Shape dome (dia: 8 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 80°C (32 to 176°F)
Body Length/Overall Length 120 mm / 195 mm
Temperature Sensor yes
Outer Diameter 12 mm
Connector Type Bluetooth Smart (Bluetooth 4.0), 10 m (33′) range
Battery Type/Life CR2032 3V lithium ion / approximately 500 hours
Amplifier yes
Recommended Use juice, must, samples with suspended solids, wine
Notes Environment: 0.0 to 50.0°C (32.0 to 122.0°F), electronic module is not waterproof
Range -2.000 to 16.000 pH / ±800 mV / -20.0 to 120.0 ºC *(will be reduced to actual probe/sensor limits)
Resolution 0.1, 0.01, 0.001 pH / 1, 0.1 mV
Accuracy (@25ºC/77ºF) ±0.005 pH / ±0.3 mV
Calibration Points Up to five points with seven standard buffers
Calibration Buffers 1.68, 3.00, 6.86, 7.01, 9.18, 10.01, 12.45 pH
Temperature Compensation Automatic from -5.0 to 100.0 ºC / 23.0 to 212.0 ºF *(will be reduced to actual probe/sensor limits)
Compatibility/System Requirements Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.
iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)
Download Information Hanna Lab App is available free from the Play Store or App Store

Manuals

HALO Bluetooth® pH Electrode for Wine – HI10482

Bestsellers

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range Checker® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

pH/EC/TDS Multiparameter Probe - HI1285-51

491.00 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor
Back to Top