Out of stock

EC Analog Controller with Input from Probe or Transmitter – HI8931

HI8931 series are panel mounted conductivity meters and controllers designed for simplicity of use in a wide range of industrial process applications.

  • Available in four models with different measurement ranges
  • Temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations
  • Backlit, LCD display for easy viewing.

Inquire Now
SKU:HI8931

Measurement Specific Models

Four different models are available with different measurement ranges, each one to be used with the corresponding HI8936 model.

In-line and Tank Use

For in-line applications, the HI7635 In-line conductivity probe – NTC sensor is recommended, while the HI7638 In-line Conductivity probe with NTC sensor for immersion, with external threads, is recommended for tanks. These probes have built-in NTC sensors for temperature compensated conductivity measurements.

Automatic Temperature Compensation

Built-in temperature sensor in recommended probes ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Use with Transmitter

Using the HI8931 in conjunction with a 4-20 mA output transmitter (HI8936 or HI8936L series) will assure a strong, interference free signal at distances up to 300 meters (1000’).

Direct Connection

HI8931 also features a direct connection up to 20 m (67’), without needing to amplify the signal to the conductivity probe.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

Specifications

SKU HI8931-web
Name EC Analog Controller with Input from Probe or Transmitter – HI8931
EC Range HI8931AN: 0.0 to 199.9 mS/cm
HI8931BN: 0.00 to 19.99 mS/cm
HI8931CN: 0 to 1999 µS/cm
HI8931DN: 0.0 to 199.9 µS/cm
EC Resolution HI8931AN: 0.1 mS/cm
HI8931BN: 0.01 mS/cm
HI8931CN: 1 µS/cm
HI8931DN: 0.1 µS/cm
EC Accuracy ±2% F.S. (excluding probe error)
EC Calibration manual, two point, through offset and slope trimmers
EC/TDS Temperature Compensation automatic, 0 to 60°C (32 to 140°F), with β = 2%/°C
Alarm Relay Set Point load, 1,000,000 strokes
Enclosure DIN 43 700, 144×72 mm (5.7×2.8 in.), black anodized aluminum; front and back with shockproof ABS plastic, and transparent cover
EC/TDS Probe HI7635 for in-line applications or HI7638 for tank (not included)
Power Supply 115 or 230 Vac ±10% (user selectable); 50/60 Hz
Environment -10 to 50°C (14 to 122°F); RH 95%
Dimensions 141 x 69 mm (5.6 x 2.7 in.)
Weight 1 kg (2.2 lb.)

Manuals

EC Analog Controller with Input from Probe or Transmitter – HI8931

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7010/1L pH 10.01 Calibration Solution (1 L)

77.00 AED
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

    Waterproof Portable Dissolved Oxygen and BOD Meter - HI98193

    2,682.00 AED
    The HI98193 is a rugged, portable dissolved oxygen (DO) meter designed for demanding applications. This professional, waterproof meter complies with IP67 standards and measures DO, barometric pressure, BOD and temperature. The HI98193 is supplied complete with all accessories to perform a DO measurement packaged into a durable carrying case.
    • Preformed PTFE Membrane
    • Quick Connect
    • Ergonomic, One-Handed Operation
    Back to Top
    Whatsapp
    Product has been added to your cart