Out of stock

Conductivity Process Digital Controller – HI720

Hanna’s innovative, high-specification 720 series conductivity controllers offer economical, constant monitoring of Electrical Conductivity (EC). HI720 is a PID, PI, proportional or on/off EC/TDS controller with one or two set points.

  • RS485 communication with additional capabilities, such as error log file downloading and cleaning commands.
  • Alarm configuration can be customized: different errors can lead different actions.
  • Mount probes directly or use a digital transmitter for large distances.

Estimated delivery: 10 - 11 September

Inquire Now
SKU:HI720-

Short Messaging Service (SMS)

It is possible to connect the controller to a GSM cellular engine (HI 504900 or HI 504901). This connection enables the instrument to send SMS to one (or two) cellular phone(s) and through this feature the device can be monitored at any moment. Moreover, if an error occurs on the HI 720, it is possible to receive an alarm SMS which immediately advises about the problem.

In-Line Cleaning

The cleaning feature allows an automatic cleaning action of the probe. Simple cleaning, with water only, can be triggered only by a timer (periodical cleaning) or by an error for which a cleaning action can be configured. Advanced cleaning, with water and detergent, it can be triggered by a variety of events.

Continuous Temperature Monitoring

Temperrature is continuously monitored using a temperature sensor (Pt100 or Pt1000 type) with ATC of conductivity. Conductivity temperature compensation parameters are fully customizable: linear or non-linear temperature compensation, reference temperature and temperature coefficient. Users can define the specific curve of temperature compensation.

Programmable Hold System

The hold function allows the user to stop the regulating action of the controller for programmable time periods. It is possible to activate the hold periods in correspondence to programmed operations, such as plant maintenance and cleaning procedures.

Logging Capabilities

The controller logging feature can save the last 100 error, configuration, calibration and cleaning events. This information can be accessed from a PC through RS485 and HI92500 software.

Fail-Safe Alarm System

Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel.

Specifications

SKU HI720-web
Name Conductivity Process Digital Controller – HI720
EC Range 0 to 2000 mS/cm (auto-ranging)
EC Resolution 1 µS/cm (0 to 1999 µS/cm)
0.01 mS/cm (2.00 to 19.99 mS/cm)
0.1 mS/cm (20.0 to 199.9 mS/cm)
1 mS/cm (200 to 2000 mS/cm)
EC Accuracy ±2% f.s.
EC/TDS Temperature Compensation Automatic or manual, -30 to 130°C
Temperature Range -30 to 130°C / -22 to 266°F
Temperature Resolution 0.1°C / 0.2°F
Temperature Accuracy ±0.5°C / ±1°F
Dosing Terminals 1, 2, 3 or 4 electromechanical relays SPDT; 5A-250 Vac, 5A-30 Vdc (resistive load); fuse protected: 5A, 250 V fuse
Alarm Relay Set Point 1 electromechanical relay SPDT; 5A-250 Vac, 5A-30 Vdc (resistive load); fuse protected: 5A, 250 V fuse
Analog Input Signal 1 or 2 independent outputs; 0-22 mA (configuring as 0-20 mA or 4-20 mA)
Digital Input Signal Digital Transmitter, Hold & Advanced Cleaning inputs
Digital Output Signal 1 digital insulated contact closed upon Hold mode
Power Consumption 10 VA
Max. Oscillation Frequency 8 MHz
Enclosure Single case 1/2 DIN
Power Supply 24 Vdc/ac, or 115 Vac or 230 Vac or 100 Vac ±10%, 50/60 Hz; fuse protected: 400 mA, 250 V fast fuse
Weight Approx. 1.6 kg (3.5 lb.)

Manuals

Conductivity Process Digital Controller – HI720

Bestsellers

Inquire Now

TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-12VDC

692 AED
The BL983315 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 199.9 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. *The BL983315 uses a 0.5 conversion factor in which 1.0 µS/cm = 0.5 ppm. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
Inquire Now

Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps, analog outputs with Panel Mounted Flow Cell Kit

7,311 AED
Control with Confidence The BL123 Swimming Pool Controller is a complete system designed for maintaining swimming pool, hot tub, and spa disinfection water quality. The BL123 is available in two configurations. The basic version is the in-line model which allows for direct installation of probe and chemical injection fittings into existing piping. The other version is a panel mounted version with a bypass flow cell. The bypass flow cell allows for calibration and maintenance of the probe without having to shut down the recirculation pump. Additional features of the BL123 include LED indicators for dosing, meter status and service, real-time graph display, programmable alarms, and password protection.
Inquire Now

Inductive Conductivity Probe – HI7650-5m (16.4')

2,552 AED
This inductive conductivity probe is designed to work with the HI720 to measure conductivity in industrial applications. With a durable PVC body and optional Pt100 temperature sensor, you can count on this electrode to stand up to your process environment.
  • Measurement is based on inductive coupling of two toroidal transformers by the liquid.
  • Models with built-in temperature sensor for Automatic Temperature Compensation.
  • Built for everyday, demanding use in industrial applications.
Inquire Now

Pool Line Calibration and Maintenance Kit ? BL123-70

26 AED
The BL123-70 Pool Line Calibration and Maintenance Kit contains all the necessary solutions to calibrate pH and ORP electrodes.
  • Convenient single-use sachets
  • 5-year shelf life for unopened sachets
  • Ideal for Service Technicians that perform routine probe maintenance
Inquire Now

HI97105 Marine Master Multiparameter Photometer-meter only

The HI97105 Marine Master Photometer combines accuracy and ease of use in a simple, portable design. The advanced optical system provides lab-quality accuracy while its user-friendly design is easy for any aquarium user making it the perfect photometer for your water quality testing needs. The HI97105 is designed to accurately determine pH, Alkalinity, Calcium, Nitrate, Nitrite, and Phosphate level in aquariums and marine biology applications.
  • No warm up time needed before taking a measurement.
  • Tutorial mode for easy step-by-step instructions.
  • CAL Check™ for performance verification and calibration.
Inquire Now

Conductivity Analog Controller with Direct Input from Potentiometric Probe - HI943500

Hanna panel mounted HI943500 series conductivity controllers are designed to meet your most demanding process control requirements. Four different models are available with different measurement ranges, to satisfy any application requirements.
  • Recorder output 4-20 mA
  • Four different models are available with different measurement ranges
  • Displays values on the easy to read LCD with backlighting
Inquire Now

TDS Mini Controller (0.0 to 49.9 ppm) - BL983324-12VDC

692 AED
The BL983324 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 49.9 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983324 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. *The BL983324 uses a 0.5 conversion factor in which 1.0 µS/cm = 0.5 ppm. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.