Active filters:
Showing 49–60 of 73 resultsSorted by popularity
PVDF Body Foodcare pH Electrode for Dairy Products and Semi-Solid Foods - FC200B
703.00 AED
The FC200B is a PVDF body, gel filled, single junction pH electrode with a BNC connector. This probe features an open junction design, a sensing bulb made of low temperature glass, and a food grade plastic body.
This design consideration is ideal for pH measurements in the food industry including dairy, dough, ground meats, and other semi-solid food samples. The recommended operating temperature range is from 0 to 50℃.
- Low Temperature Glass
- Open Junction
Portable Meat pH Meter - HI99163
The HI99163 is a portable Foodcare pH/temperature meter specially designed for the meat processing industry. Automatic calibration is performed at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature variations.The HI99163 uses the PVDF body FC2323 amplified pH electrode that offers numerous features to improve pH testing for meat processors. The probe comes with the FC099 removable stainless steel blade to help users perform non-intrusive measurements of meat products, inside and out. The free diffusion junction helps to avoid a clogged reference and the external body material is non-toxic and food compatible.
- Automatic Temperature Compensation
- Automatic Two-Point Calibration
- Waterproof
Portable Waterproof pH/EC/TDS Meter (High Range) - HI991301
1,988.00 AED
The HI991301 is designed to measure pH, conductivity (EC), total dissolved solids (TDS), and temperature with a single probe. From setup to calibration all operations are performed with just two buttons. The meter is waterproof and rated for IP 67 conditions.The HI12883 pre-amplified multiparameter probe features an easy-to-clean sensor and a cloth junction that can be renewed to increase the life of the probe. To ensure against interference from transient electrical noise, a solid-state amplifier is integrated into the HI12883.User-selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (β) from 0.0 to 2.4% for greater consistency and reproducibility. Standardized buffer recognition values are also selectable.These instruments easily fit in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in your way. The large, multi-level LCD displays the primary reading, temperature, and calibration guides simultaneously.
Waterproof Portable pH/Temperature Meter - HI991001
The HI991001 is a compact, waterproof, portable pH/temperature meter that is supplied complete including a rugged carrying case and a unique titanium body pH electrode that has a built-in temperature sensor. The meter features a large, dual level LCD display for easy viewing of the pH, temperature, and status indicators. The operation of the meter is simplified to two buttons. The HI991001 has an exceptional long battery life of 1400 hours of continuous use.
- Automatic Temperature Compensation
- Automatic Two-Point Calibration
- Waterproof
Waterproof pHep®5 pH/Temperature Tester - HI98128
433.00 AED
Hanna's pHep®5 is an advanced, ergonomic, waterproof pH and temperature tester, with 0.01 resolution, that measures from -2.0 to 16.0 pH pH and accuracy of ±0.05 pH. pHep5 features automatic one or two-point calibration to known buffer and automatic temperature compensation.
- Waterproof
- Replaceable pH Electrode
- Automatic up to Three-Point pH Calibration
Checker® pH Tester with 0.1 pH Resolution - HI98103
132.00 AED
The HI98103 Checker is the next generation of the original Hanna Checker pH tester. The Checker is the most popular pH meter in the world with over 1 million meters used since its introduction in 1991. From students to researchers, the Checker has been helping people with their pH measurement as a meter that is simple to use and operate.
- One-button operation
- Replaceable pH electrode
- ±0.2 pH accuracy
HI80300L Electrode Storage Solution in FDA Bottle (500 mL)
HI80300L is a storage solution that is supplied in an FDA compliant bottle. It is prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI80300L storage solution for at least one hour before taking measurements.
- Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
- Manufactured specifically for pH and ORP electrodes
- Clearly marked expiration date and lot number
Inquire Now
Marine Ammonia HC Checker Reagents (25 tests) - HI784-25
HI784-25 Marine Ammonia Checker HC (Handheld Colorimeter) Reagents are high-quality reagents for use with the HI784 Marine Ammonia (ppm) Checker HC. Reagents are clearly marked with the lot number and expiration date on each packet for traceability.
- Pre-made reagents for ease of use
- Prepared with high-purity chemicals
- Marked with expiration date and lot number for traceability
HI7073L Cleaning Solution for Proteins (500 mL)
119.00 AED
The HI7073L is a special enzymatic cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with proteins. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
- Specially formulated cleaning solution to remove proteins from a pH electrode
- Air tight bottle with tamper-proof seal to ensure quality
- Expiration date and lot number clearly marked on the bottle
HI70671L Cleaning & Disinfection Solution for Algae, Fungi and Bacteria (500 mL)
129.00 AED
The HI70671L is an effective, acidic effective cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with algae, fungi and bacteria. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Specially formulated cleaning solution to remove bacterial products from a pH electrode
- Air tight bottle with tamper-proof seal to ensure quality
- Expiration date and lot number clearly marked on the bottle
HI70670L Cleaning Solution for Salt Deposits (500 mL)
129.00 AED
The HI70670L is an effective, acidic cleaning solution that is specially formulated for use in industrial applications that permit electrodes to come into contact with salts. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Specially formulated cleaning solution to remove salt deposits from a pH electrode
- Air tight bottle with tamper-proof seal to ensure quality
- Expiration date and lot number clearly marked on the bottle
HI7010M pH 10.01 Calibration Solution (230 mL)
54.00 AED
HI7010M is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle

























