Turbidity Calibration Standards for HI98713 – HI98713-11

The HI98713-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.

  • Supplied with Certificate of Analysis

  • Standard values of <0.1, 15, 100, and 750 FNU
  • Reusable with long shelf life stability

433.00 AED

Estimated delivery: 25 - 26 April

Inquire Now
SKU:HI98713-11

The nephelometric turbidity meter is designed to be routinely standardized with a known light scattering standard. As with all analytical standards or reference materials, a turbidity standard should be able to perform the following: provide traceability, demonstrate the accuracy of results, calibrate the equipment and methodology, monitor user performance, validate tests, and facilitate comparability. Standardization ensures that when the correct procedures have been followed, the same analysis of the same materials will produce results that agree with each other whenever they are performed.

Hanna turbidity standards are prepared from AMCO AEPA-1 materials that are known for being highly stable and reliable for standardization. AMCO APEA-1 turbidity standards are a stabilized suspension of cross linked styrene divinylbenzene copolymer microbeads in ultrapure water. These beads are chemically inert and keep their chemical balance in a water medium regardless of concentration. Particle size, uniform shape, and refractive index make these spheres ideal to characterize light absorption and scatter for 90° behavior in the UV-VIS range. In addition, the bead’s spherical shape and size helps prevent the accumulation or precipitation of the standard. For these reasons, the AMCO AEPA-1 standards are very stable.

These standards are prepared and bottled in a clean room facility. They are tested and validated for accuracy and stability, and certified as free from any toxic chemicals or compounds. All prepared standards are compared to formazin turbidity standard solutions. The values obtained and the date of analysis are reported on the supplied certifcate of analysis.

HI98713-11 is a high quality set of turbidity calibration standards that allows users to validate and calibrate turbidity meters that have a 0 to 1000 FNU range. The HI98713-11 set includes four cuvettes with expected readings of 0.1, 15, 100, and 750 FNU. The calibration set is produced in our state-of-the-art manufacturing facility using NIST traceable reference materials in a temperature controlled environment.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

Checking the turbidity range for the HI98713 ISO Turbidity Portable Meter is quick and easy with the HI98713-11 Turbidity Calibration Standards.

Specifications

SKU HI98713-11
Name Turbidity Calibration Standards for HI98713 – HI98713-11
Package Sealed standards: <0.1, 15, 100, 750 FNU
Quantity 1 set

Manuals

Turbidity Calibration Standards for HI98713 – HI98713-11

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart