Out of stock

TDS Mini Controller (0 to 1999 ppm) – BL983319-1 | 115/230VAC

The BL983319 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) in a process stream that is within the 0 to 1999 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is below the set point. The relay can be used to supply power to a dosing pump to add fertilizer to a nutrient solution in order to maintain an ideal concentration.

*The BL983319 uses a 0.65 conversion factor in which 100 µS/cm = 65 ppm.

Multicolor LED Indicator

LED changes color based on status.

Fire Retardant Casing

For additional safety the controllers outer case is made of fire resistant plastic.

Splash Resistant Cover

A clear plastic cover protects the face panel from dirt and liquids.

734.00 AED

Estimated delivery: 30 - 31 March

Inquire Now
SKU:BL983319-1
BL983319

Adjustable Dry Contact Dosing Relay

The BL983319 features a dosing relay that is activated when the reading is below a user programmable set point.

Programmable Overdose Protection

For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.

Relay Control Override

With the flick of a switch the mini controller’s relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolor LED Indicator

Multicolor LED indicator allows an operator to quickly check the status of the controller.

  • Green = Meter in measurement mode and reading is below the set point.
  • Orange/Yellow = Reading is above the set point and the relay is activated.
  • Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
BL983319

Fuse Protected Dosing Contacts

The relay dosing contact is rated for up to a 2A load and is fuse protected.

Labeled Termination Connections

Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

HI7634

1/2″ NPT Male Threaded Amperometric Probe for Mounting In-line*

The BL983319 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.

*HI7634 is not included and must be ordered separately

Specifications

SKU BL983319-1
Name TDS Mini Controller (0 to 1999 ppm) – BL983319-1 | 115/230VAC
TDS Range 0 to 1999 ppm (mg/L)
TDS Resolution 1 mg/L ppm (mg/L)
TDS Accuracy ±2% f.s.
TDS Calibration manual, with CAL trimmer
EC/TDS Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/oC
EC to TDS Conversion Factor 0.65
EC/TDS Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC
EC/TDS Dosing Set Point adjustable from 0 to 1999 mg/L (ppm)
Dosing Control contact closed when measure < setpoint
Over Dosing Control adjustable, typically from 5 to approximately 30 minutes
Power Supply models “-0”: 12 VDC adapter (included)
models “-1”: 115/230 VAC; 50/60Hz
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)
Weight models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)

Ordering Info

BL983319-1 (115/230 VAC) and BL983319-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.

Manuals

TDS Mini Controller (0 to 1999 ppm) – BL983319-1 | 115/230VAC

Bestsellers

Inquire Now

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Inquire Now

    HI7022L 470 mV @ 25°C ORP Test Solution (500 mL)

    119.00 AED
    HI7022L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality
    Inquire Now

    edge® Dedicated pH/ORP Meter - HI2002

    1,583.00 AED
    Hanna Instruments is proud to introduce the world’s most innovative pH/ORP meter: edge®. edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. edge is a single, easy to use meter that can measure pH and ORP.Advanced pH Electrode Diagnostics edge features advanced pH electrode diagnostics to ensure worry-free measurements. Diagnostics include Hanna’s exclusive CAL Check™ feature that alerts users to potential problems during calibration. The Sensor Check™ feature for glass and junction integrity is enabled when using optional pH electrodes with a matching pin.Capacitive Touch edge features a capacitive touch keypad that gives a distinctive, modern look. The keypad has a fast response and is sensitive enough to be used with laboratory gloves. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue.Large, Easy to Read LCD edge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCDs in the industry.
    Back to Top
    Whatsapp
    Product has been added to your cart