In stock

Silicon oil for turbidity meter

HI98703-58 silicone oil is for use with Hanna’s line of turbidity meters. This easy to use dropper bottle ensures the glass cuvette used for turbidimetric measurements remains free from imperfections and scratches, helping to provide accurate readings every time.

  • Convenient dropper bottle
  • Marked with lot number and expiration date
  • Light tight bottle

94.00 AED

Estimated delivery: 23 - 24 December

SKU:HI98703-58

The glass cuvette is an important component of the optical system in all colorimetric and turbidimetric measurements. Light reaches the sample by first passing through the cuvette glass. Based on the sample, the light is absorbed, transmitted, or scattered. As a result, the measurement can be affected if the cuvette glass has imperfections, dirt, dust, scratches, or fingerprints present.

To hide minor imperfections and scratches, the outer surface of the cuvettes should be oiled with the HI98703-58 silicone oil. The silicone oil has the same refractive index as the glass and will not alter the turbidity readings. Applying silicone oil is very important, especially for low turbidity samples (< 1 NTU), as scratches and imperfections in the glass can alter turbidity readings. Simple apply a few drops of oil onto a clean, dry cuvette and wipe thoroughly with a lint-free cloth. Wipe off the excess oil till you obtain a thin, uniform layer and the cuvette appears nearly dry, with no visible oil.

Bestsellers

HI731336N Caps for Glass Cuvette Used with HI977 Series Portable Photometers (4 pcs)

59.00 AED
The HI731336N are the replacement caps that screw on the glass cuvettes used with the HI977xx series portable photometers. Each cap has a locking indexing tab that ensures the cuvette is inserted into the photometer in the same position. The caps are also used to block any light that would interfere with the optically based measurement. The HI731336N includes 4 caps.
  • Locking index tab for proper alignment in the photometer
  • Light blocking to prevent stray light from entering

Silicon oil for turbidity meter

94.00 AED
HI98703-58 silicone oil is for use with Hanna's line of turbidity meters. This easy to use dropper bottle ensures the glass cuvette used for turbidimetric measurements remains free from imperfections and scratches, helping to provide accurate readings every time.
  • Convenient dropper bottle
  • Marked with lot number and expiration date
  • Light tight bottle

Replacement temperature probe for HI931& HI932 titrators

309.00 AED
Replacement temperature probe for HI931& HI932 titrators
Inquire Now

HI2003/5 Standard Model ORP/PT Electrode

800.00 AED
HI-1000 and HI-2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quickly and easily. Models with 3 or 5 metre cables are available.

1 mL Graduated Syringe (6 pcs)

59.00 AED
HI740143 is a package of 6 graduated syringes for accurate dosing reagents for chemical test kits and photometers.
  • 1mL capacity
  • 6 syringes per set
  • Ideal for for accurate reagent dosing for CTK and photometers
Inquire Now

Replacement temperature probe for HI5XXX research grade benchtops

309.00 AED
Replacement temperature probe for HI5XXX research grade benchtops
Inquire Now

HI5321 Research Grade EC/TDS Meter with USP (230V)

3,839.00 AED
HI-5321 can be used to perform all 3 stages of USP method required for conductivity measurement of pure and ultra-pure water.
Back to Top
Whatsapp
Product has been added to your cart