Replacement pH Assembly for Ammonia ISE – HI4000-51

The HI4000-51 is a replacement pH reference assembly for the HI4101 ammonia gas sensing ion selective electrode.

Combination pH assembly

pH sensitive membrane

Stable reference electrode

AED

Estimated delivery: 20 - 21 May

SKU:HI4000-51

The HI4000-51 replacement pH reference assembly is for use with Hanna’s HI4101 ammonia gas sensing ion selective electrode (ISE). This internal glass pH assembly provides the sensing and reference components for the ammonia combination ISE.

Theory of Operation

A gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diŽffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.

Specifications

SKU HI4000-51
Name Replacement pH Assembly for Ammonia ISE – HI4000-51

Manuals

Replacement pH Assembly for Ammonia ISE – HI4000-51

Bestsellers

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

pH Electrode for Process Control and Monitoring - HI1001

583 AED
The HI1001 is a flow-thru monitoring pH electrode with BNC connection and 3 m cable that has been specifically built for industrial applications. This durable electrode is composed of a PVDF body with a protective PEI sleeve around the glass bulb for resistance against mechanical stress. This sensor provides a rapid response and high accuracy pH measurements for industrial applications.
  • 1/2" NPT threads for in-line mounting
  • PTFE junction
  • BNC universal connector

HI8006L/C pH 6.86 Calibration Buffer in FDA Bottle (500 mL)

117 AED
HI8006L/C is a premium quality pH 6.86 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. The buffer is contained in an opaque, light-tight bottle that meets FDA requirements. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Silica High-Range Checker® HC - HI770

223 AED
The Hanna Silica High-Range Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Silica High-Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.
  • Compact, Portable Design
  • Built-in Timer
  • One-Button Operation

HI7007M pH 7.01 Calibration Solution (230 mL)

48 AED
HI7007M is a premium quality pH 7.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Nitrite Medium-Range (16 mm Vial) Reagents (25 tests) – HI96784-25

208 AED
The HI96784-25 are reagents for the colorimetric determination of nitrite. There are enough reagents for 25 tests to be used with Hanna’s compatible photometers. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number

HI7075 Electrolyte Solution 1.7M KNO₃, 0.7M KCl (30 mL x 4)

153 AED
HI7075 is a fill solution that contains 1.7M potassium nitrate (KNO3), 0.7M potassium chloride (KCl) for use in fluoride ion selective electrodes. The electrolyte level in refillable electrodes should be topped off before performing any measurements. If the level is low, refill with the proper electrolyte solution to ensure optimum performance. This simple maintenance helps guarantee adequate head pressure to promote the flow of reference electrolyte into the sample being measured.
  • Fill solution for fluoride ISE
  • Convenient 30 mL bottles
  • Expiration date and lot number clearly marked on the bottle
Back to Top
img
Product has been added to your cart