Out of stock

Refillable PEI Body pH Electrode with BNC + Pin Connector – HI1332P

The HI1332P is a PEI body, double junction pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters.

This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with general purpose glass and is protected by an extension of the durable PEI body. This design consideration is ideal for field applications as well as general purpose use.

Durable PEI Body

Double Junction Design

Refillable Electrode

549.00 AED

Inquire Now
SKU:HI1332P

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1332P uses general purpose (GP) glass, spherical bulb, polyetherimide (PEI) body, single ceramic frit, and double junction.

Glass

General Purpose Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25ā„ƒ while the resistance of LT glass is around 50 megaohms at 25ā„ƒ. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI1332P is suitable to use with samples that measure from 0 to 70ā„ƒ.

Spherical Bulb

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

PEI Body

PEI Body

The body of the HI1332P is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.

Double Junction

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

din connector

BNC + Pin Connector

The HI1332P uses a BNC + Pin connector. The BNC type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. The pin connector is used to enable the CAL Check function on the following benchtop pH meters; HI122, HI123, HI221, HI222, HI223, HI2221, HI2222, and HI2223.

single vs double junction

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the Āfigure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihoodof clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate that can form to clog the junction.

Specifications

SKU HI1332P
Name Refillable PEI Body pH Electrode with BNC + Pin Connector – HI1332P
Measurement Range pH: 0 to 13
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl
Body Material PEI
Tip / Shape spheric (dia: 7.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 70°C (32 to 158°F) – GP
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC + pin
Amplifier no
Recommended Use chemicals, field applications, quality control

Manuals

Refillable PEI Body pH Electrode with BNC + Pin Connector – HI1332P

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Inquire Now

HALOĀ® BluetoothĀ® Wireless pH Meter for Flat Surfaces - HI14142

989.00 AED
The HI14142 HALO is an innovative pH electrode with BluetoothĀ® Smart technology designed for flat surfaces Our HALOĀ® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edgeĀ®blu. One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology. Status Indicator Visible from a distance, the LED ā€œhaloā€ light flashes to indicate the status of the probe. Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.
Back to Top
Whatsapp
Product has been added to your cart