Out of stock

pH Electrode with Built-In Temperature Sensor and DIN Connector – HI1610D

The HI1610D is a glass body, refillable, single junction pH electrode with a DIN connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with general purpose glass.

This pre-amplified electrode features a built-in temperature sensor for temperature compensated measurements in a single probe design. This design consideration is ideal for laboratory and general purpose use. The HI1610D is recommended for use with Hanna’s HI8314 pH meter.

Built-In Temperature Sensor

Single Ceramic Junction

Refillable Electrode

664.00 AED

Inquire Now
SKU:HI1610D

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1610D uses general purpose (GP) glass, spherical bulb, glass body, single ceramic junction and is refillable with 3.5M KCl + AgCl.

Glass

General Purpose Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25ā„ƒ while the resistance of LT glass is around 50 megaohms at 25ā„ƒ. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI1610D is suitable to use with samples that measure from 0 to 70ā„ƒ.

Flat Tip

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

glass Body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

 

Single Ceramic Junction

The outer junction of an electrode, also known as a salt bridge, is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

 

Refillable

Refillable

The HI1610D is a refillable probe. Since it is a single junction pH electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable pH electrode, the fill cap should be removed prior to calibration and measurement. Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

DIN connector

DIN Connector

The HI1610D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI1610D is recommended for use with Hanna’s HI8314 pH meter. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few.

Specifications

SKU HI1610D
Name pH Electrode with Built-In Temperature Sensor and DIN Connector – HI1610D
Measurement Range pH: 0 to 13
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Refill Electrolyte 3.5M KCl + AgCl
Body Material glass
Tip / Shape spheric (dia: 9.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 70°C (32 to 158°F) – GP
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 5-pole; 1 m (3.3 in.)
Connector Type DIN
Amplifier yes
Recommended Use laboratory general purpose

Manuals

pH Electrode with Built-In Temperature Sensor and DIN Connector – HI1610D

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafeā„¢ mechanism Adjustable speed control
Inquire Now

edgeĀ® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5ā€ thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

Foodcare pH Electrode for Semi-Solid with Quick Connect DIN Connector - FC2023

788.00 AED
The FC2023 is an amplified double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The FC2023 electrode featuresĀ a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape.Ā This design consideration is ideal for pH measurements in dairy products, emulsions, cream, or other semi-solid samples. The recommended operating temperature range is fromĀ 0 to 50ā„ƒ.
  • Low Temperature Glass
  • PVDF Body
  • Open Junction
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.
Back to Top
Whatsapp
Product has been added to your cart