Out of stock

pH Electrode Storage Solution (30 mL)

HI70300S is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300S storage solution for at least one hour before taking measurements.

  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

33.00 AED

Inquire Now
SKU:HI70300S

HI70300S is a solution that can be used to store your pH electrode*. To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. The HI70300S should also be used to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements.

Screen Shot 2015 01 23 at 3.44.52 PM

* Never store pH or ORP electrodes in distilled or deionized water. Doing so will shorten the life of the sensor.

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

Each bottle marked with lot number and expiration date.

  • Hanna storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Specifications

SKU HI70300S
Name pH Electrode Storage Solution (30 mL)
Description pH Electrode Storage Solution (30 mL)
Package dropper bottle
Size 30 mL

Manuals

pH Electrode Storage Solution (30 mL)

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

HI7010/1L pH 10.01 Calibration Solution (1 L)

77.00 AED
HI7010/1L is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Solution dyed violet for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    703.00 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
    Back to Top
    Whatsapp
    Product has been added to your cart