Out of stock

pH Electrode for Beer Analysis – FC2143

The FC2143 is a titanium body, gel filled, single reference junction pH electrode. This electrode features low temperature glass and an extendable cloth type junction, along with a built-in temperature sensor and amplifier in a single probe design.

This design consideration is ideal for measuring the pH of mash or wort during the beer making process. The FC2143 is the replacement pH/temperature probe supplied with the HI99151 portable meter for beer.

  • Low Temperature Glass
  • Titanium Body
  • Built-in Temperature Sensor

723.00 AED

Inquire Now
SKU:FC2143

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC2143 uses high temperature (HT) glass, spherical bulb, titanium body, and cloth junction with gel electrolyte.

high temperature glass

Low Temperature Glass Formulation

The Low Temperature (LT) glass formualtion allows for the shape of the pH sensitive glass to be flat. The FC2143 is suitable to use with samples that measure from 0 to 80℃.

spherical bulb

Flat Tip Bulb

The recessed flat tip bulb of the FC2143 is easy to clean and prevents solids in solutions from collecting on the sensor. Other tip shapes include conic for penetration and spheric for aqueous measurements.

titanium body

Titanium Body

A pH measurement is a very sensitive voltage measurement that is susceptible to interference from electrical noise and humidity.  To overcome these issues a titanium body serves as a matching pin. A matching pin is a differential measurement technique used to eliminate electrical noise in the measurement system. The titanium body, being made of metal, is virtually unbreakable and  offers additional protection from accidental breakage.

cloth junction

Cloth Junction

Every pH electrode has a junction. They can be made from a variety of material including ceramic, PTFE, and a fiber wick. The fiber wick is also known as a cloth junction and is often used on electrodes with gelled electrolytes. The advantage of the cloth junction is that it can be extracted from the probe exposing a fresh surface. This is very important since one of the major contributors to unstable measurements is a clogged junction. This is likely to occur when measuring the pH of mash that has a high solids content. Having the ability to pull out a small portion (⅛”) of the junction will clear any clogging resulting in an increased life of the pH electrode.

din connector

DIN Connector

The FC2143 uses a quick connect DIN connector. This type of connector is proprietary to the meter they are to be used with. The FC2143 is the replacement electrode for the HI99151. Other type of connectors include BNC, screw type, T-type, and 3.5mm.

Specifications

SKU FC2143
Name pH Electrode for Beer Analysis – FC2143
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate cloth
Type of Electrolyte gel
Body Material titanium
Glass Type Low Temperature (LT) glass
Tip / Shape flat tip
Optimum pH Range pH: 0 to 12
Temperature Operating Range 0 to 80°C (32 to 176°F)
Body Length/Overall Length 105 mm / 145.5 mm
Temperature Sensor yes
Outer Diameter 14 mm
Cable 7-pole; 1 m (3.3 in.)
Connector Type quick connect DIN connector
Amplifier yes
Recommended Use beer, mash, wort

Manuals

pH Electrode for Beer Analysis – FC2143

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart