Out of stock

Mini Titrator for Measuring Sulfur Dioxide in Wine – HI84500-01

The HI84500 is a simple, fast, and affordable automatic mini titrator designed for testing free or total sulfur dioxide (SO2) levels in wine. Based on the Ripper Method, this mini titrator uses an optimized, preprogrammed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a specialized ORP electrode.The HI84500 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage changed. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.This mini titrator is supplied complete with all the materials necessary to perform low and high range measurement of SO2. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.

  • Piston driven pump for accurate dynamic dosing
  • Complete with ORP electrode with CPS™ Technology
  • Pre-standardized titrant and pre-measured reagents

4,230.00 AED

Estimated delivery: 25 - 26 April

Inquire Now
SKU:HI84500-01

The HI84500 can be used to test for free and total SO2 in all wines, including red, which are difficult to test using traditional methods due to the inability to see the distinctive color change that occurs at the endpoint. The HI84500 offers a reliable, accurate, and fast way to analyze free and total sulfur dioxide. This mini titrator dispenses the titrant, detects the endpoint, and performs all necessary calculations automatically in a fraction of the time as compared to a manual titration. As found inTriage for Basic Wine/Grape Lab by Richard Carey, “the mini-titrator by Hanna reduces the time for an individual analysis by 75%.”Winemakers add sulfur dioxide (SO2) to wine in order to inhibit bacteria and wild yeast growth and to serve as an antioxidant to prevent browning. When SO2 is added to wine, a portion of it becomes immediately bound while a remaining portion is unbound SO2. The portion that is unbound is also called free SO2 and it is responsible for protecting the wine. The bound and free SO2 together are referred to as total SO2. The relationship between the amount of SO2 added and the amount of free SO2 is complex, governed by the total amount of SO2 in the wine and the ability of compounds (e.g. sugars, aldehydes, keto acids, quinones, anthocyanin) to bind to the SO2. The exact relationship between free and bound SO2 will vary from wine to wine.The amount of free SO2 depends on how much is added, how much was present before the addition, and how much was immediately bound. Free SO2 exists in two forms. The first form, bisulfite (HSO3), is the predominant form but is relatively ineffective. The second form, molecular SO2, is the minor form and is responsible for protecting the wine. The amount of molecular SO2 available in wine is dependent upon the amount of free SO2 present and the pH. Typically 0.8 ppm of molecular SO2 provides adequate protection against bacteria growth and oxidation. In order to obtain this value for a wine sample that has a pH of 3.2 you would need 22 ppm of free SO2. If the pH was at 3.5 you would need double the amount of free SO2, 44 ppm. 

pH

3.0

3.1

3.2

3.3

3.4

3.5

3.6

3.7

3.8

3.9

Free SO2

14

18

22

28

35

44

55

69

87

109

Application-Specific ORP Electrode The HI84500 is supplied with the HI3148B ORP electrode featuring CPS™ technology to prevent the clogging of the reference junction. Conventional electrodes may clog quickly in samples such as wine that have a high suspended solids content. By design, the HI3148B ORP electrode utilizes a ground glass/PTFE sleeve junction which controls a steady, predictable flow of electrolyte solution, keeping the junction open. The hydrophobic properties of PTFE repel wetness and coatings.Piston Driven Dosing Pump The heart of the HI84500 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.Automatic Stirrer The built-in stirrer is automatically maintained at a speed of 700 rpm, regardless of the viscosity of the solution being titrated. 

On-Screen Features

titrator screenshot

Easy-to-Use Interface The HI84500 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.

Titrate LR

Procedure Warnings Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.

mini titrator so2 graphic mode

Graphic Mode This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.

mini titrator so2 logging

Log-on-Demand The HI84500 allows for data logging of up to 400 samples: 200 titration results and 200 ORP/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.

mini titrator so2 orp mv meter

ORP/mV Meter In addition to being an automatic titrator, the HI84500 also can be used as an mV meter for direct ORP measurements.

Low RangeHigh Range
HI84500-50 Low Range Titrant (230 mL)HI84500-51 High Range Titrant (230 mL)
HI84500-55 Calibration Standard (120 mL)HI84500-55 Calibration Standard (120 mL)
HI84500-60 Acid Reagent (230 mL)HI84500-60 Acid Reagent (230 mL)
HI84500-61 Alkaline Reagent (120 mL)HI84500-61 Alkaline Reagent (120 mL)
HI84500-62 Stabilizer packets (100 pcs)HI84500-62 Stabilizer packets (100 pcs)

Specifications

SKUHI84500-01
NameMini Titrator for Measuring Sulfur Dioxide in Wine – HI84500
pH-mV Range-2000.0 to 2000.0 mV
pH-mV Resolution0.1 mV
pH-mV Accuracy±1.0 mV (@25ºC/77ºF)
Titration MethodRipper method
Titration Principleequivalence point redox titration
Titration RangeLow Range: 1.0 to 40.0 ppm of SO2; High Range: 30 to 400 ppm of SO2
Titration ResolutionLow Range: 0.1 ppm; High Range: 1 ppm
Titration AccuracyLow Range: 3% of reading or ±0.5 ppm, whichever is greater; High Range: 3% of reading or ±1 ppm, whichever is greater (@25ºC/77ºF)
Sample Size50 mL
Titration Pump Speed10 mL/min
ORP ElectrodeHI3148B glass body ORP electrode with BNC connector and 1 m (3.3’) cable (included)
Logging Typelog-on-demand
Logging Memoryup to 400 (200 titrations, 200 ORP/mV readings)
Built-in Magentic StirrerBuilt-in magnetic stirrer at 700 rpm
Power Supply12 VDC adapter (included)
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)
Weight1.9 kg (67.0 oz.)

Ordering Info

HI84500-01 (115V) is supplied with HI3148B ORP electrode, HI7082 electrode fill solution (30 mL), HI84500-50 low range titrant (230 mL), HI84500-51 high range titrant (230 mL), HI84500-55 calibration standard (120 mL), HI84500-60 acid reagent (230 mL), HI84500-61 alkaline reagent (120 mL), and HI84500-62 stabilizer packets (50 packets), 100 mL beakers (2), 20 mL beakers (2), scissors, dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, cleaning solution sachets for wine deposits (2), cleaning solution sachets for wine stains (2), 12 VDC adapter and instruction manual.

Manuals

Mini Titrator for Measuring Sulfur Dioxide in Wine – HI84500

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007L pH 7.01 Calibration Solution (500 mL)

61.00 AED
HI7007L is a premium quality pH 7.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

    114.00 AED
    HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Prepared with reagent grade chemicals
    • Allows for a quick check of your ORP electrode
    • Air tight bottle with tamper-proof seal to ensure quality

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass
    Inquire Now

    Conductivity (EC) Controller (0.0 - 199.9 µS/cm) - BL983320-1 | 115/230VAC

    734.00 AED
    The BL983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 µS/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. Multicolor LED Indicator LED changes color based on status. Fire Retardant Casing For additional safety the controllers outer case is made of fire resistant plastic. Splash Resistant Cover A clear plastic cover protects the face panel from dirt and liquids.
    Back to Top
    Whatsapp
    Product has been added to your cart